Return to study ST001845 main page

MB Sample ID: SA171648

Local Sample ID:840422-24_016
Subject ID:SU001922
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:23-73
Gender:Male and female
Human Race:Hispanic and Caucasian

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001922
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:23-73
Gender:Male and female
Human Race:Hispanic and Caucasian

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
840422-24_016SA171648FL020628NAFLD-CAUfactor

Collection:

Collection ID:CO001915
Collection Summary:Blood was collected as a part of a routine/pre-operation check up, not more than 2 weeks prior to operation day (bariatric surgery) for the NAFLD group and among normal BMI healthy volunteers for the control group. All volunteers were fasted 10-12 hours before collection. Liver obtained during surgery (no preservatives, flash-frozen)
Sample Type:Blood

Treatment:

Treatment ID:TR001934
Treatment Summary:Subjects were divided into two groups either: Healthy control or Nonalcoholic fatty liver disease (NAFLD)

Sample Preparation:

Sampleprep ID:SP001928
Sampleprep Summary:1 Thaw plasma samples on ice 2 Vortex plasma sample and pipette 50µl in polypropylene Eppendorf tube/Plate 3 Add Surrogate Standards of the 3 lipid classes (as needed) and other reagents as in the following table: Plasma Sample 10x Oxylipid Surrogate STDs CUDA + PHAU Anti-oxidant ACN/MeOH SUM 4 Vortex for 30sec 5 Centrifuge at 6°C for 5 min at 15,000 g (or 1,800 g for plates) 6 Take the supernatant (~240µl) into new Eppendorf tube/filter plate 7 Spin Filter (0.1 um) or plate filter (0.2um) for 5 min @ 12,000 g (1,800g for plate) 8 place aliquotes of samples into vials, or plate, and cap vials or seal plates 9 Store in -20°C until analysis

Combined analysis:

Analysis ID AN002988
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Vanquish
Column Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type EI
MS instrument type Other
MS instrument name ABI Sciex 4000 QTrap
Ion Mode UNSPECIFIED
Units nM

Chromatography:

Chromatography ID:CH002217
Chromatography Summary:Targeted oxylipin analysis
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Chromatography Type:HILIC

MS:

MS ID:MS002778
Analysis ID:AN002988
Instrument Name:ABI Sciex 4000 QTrap
Instrument Type:Other
MS Type:EI
MS Comments:analyzed by a Waters UPLC with a 2.1×150 mm, 1.7 µm Acquity BEH column, ESI (+) and (-) switching and detection by multi-reaction monitoring on an Sciex 6500+ QTRAP mass spectrometer. We validated this method for linearity, limit of detection, limit of quantitation, inter- and intra-day reproducibility, and recovery for all targets, yielding better than 15% relative standard deviation and (spiked) recoveries of greater than 80%.
Ion Mode:UNSPECIFIED
  logo