Return to study ST001915 main page
MB Sample ID: SA177710
Local Sample ID: | WT_ZT10_3 |
Subject ID: | SU001993 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU001993 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
WT_ZT10_3 | SA177710 | FL021969 | WT_ZT10 | Group |
WT_ZT10_3 | SA177710 | FL021969 | wild type control | Genotype |
WT_ZT10_3 | SA177710 | FL021969 | WT mouse heart ventrcle harvest at ZT10 | Experimental variables |
Collection:
Collection ID: | CO001986 |
Collection Summary: | Snap-frozen heart ventricles were collected from both WT and Rev-erb cardiomyocyte-specific KO mice at ZT10 or ZT22 |
Sample Type: | Heart |
Treatment:
Treatment ID: | TR002005 |
Treatment Summary: | no special treatment |
Sample Preparation:
Sampleprep ID: | SP001999 |
Sampleprep Summary: | Heart ventricle tissues were harvested from male mice at 3 months old (n = 3 at each condition) and were snap-frozen in liquid nitrogen. Lipids were extracted as previously described 55–57. Lipids were separated on a Shimadzu CTO-20A Nexera X2 UHPLC systems, 1.8 μm particle 50 × 2.1 mm Acquity HSS UPLC T3 column (Waters, Milford, MA). Lipidomics acquisition performed in both pos and neg mode ionization. Pos mode lipids were normalized by Internal Standard PC 17:0; [M+H]+, Neg mode lipids were normalized by Internal Standard PC 34:0. |
Combined analysis:
Analysis ID | AN003113 |
---|---|
Analysis type | MS |
Chromatography type | GC |
Chromatography system | Shimadzu Nexera X2 |
Column | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | EI |
MS instrument type | Other |
MS instrument name | Shimadzu QP2010 Plus |
Ion Mode | UNSPECIFIED |
Units | pmoles/l |
Chromatography:
Chromatography ID: | CH002298 |
Instrument Name: | Shimadzu Nexera X2 |
Column Name: | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
Chromatography Type: | GC |
MS:
MS ID: | MS002894 |
Analysis ID: | AN003113 |
Instrument Name: | Shimadzu QP2010 Plus |
Instrument Type: | Other |
MS Type: | EI |
MS Comments: | Statistical analyses were performed with either ANOVA or t-test in R Studio (R Studio Inc., Boston, MA). Differential metabolites were identified by adjusting the p-values for multiple testing at an FDR (Benjamini Hochberg method) threshold of <0.25. |
Ion Mode: | UNSPECIFIED |