Return to study ST001991 main page

MB Sample ID: SA186034

Local Sample ID:5004186
Subject ID:SU002072
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002072
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
5004186SA186034FL02301112Age
5004186SA186034FL0230111sex
5004186SA186034FL023011CTRCase

Collection:

Collection ID:CO002065
Collection Summary:The DIABIMMUNE study recruited 832 families in Finland (Espoo), Estonia (Tartu), and Russia (Petrozavodsk) with infants carrying HLA alleles that conferred risk for autoimmunity. The subjects involved in the current study were chosen from the subset (n = 74) of international DIABIMMUNE study children who progressed to at least a single AAb (P1Ab, n = 23), who progressed to multiple islet AAb (P2Ab, n = 13), and controls (CTRs, n = 38), i.e. the children who remained islet AAb- negative during the follow-up in a longitudinal series of samples collected at 3, 6, 12, 18, 24 and 36 months from each child (Kostic et al. 2015). The study groups were matched for HLA-associated diabetes risk, sex, country and period of birth. This study was conducted according to the guidelines in the Declaration of Helsinki. The Ethics and Research Committee of the participating Universities and Hospitals approved the study protocol. All families provided written informed consent prior to sample collection.
Sample Type:Blood (serum)
Storage Conditions:-80℃

Treatment:

Treatment ID:TR002084
Treatment Summary:The bile acids were measured in serum and fecal sample as described previously (Jäntti et al., 2014; Salihović et al., 2020).

Sample Preparation:

Sampleprep ID:SP002078
Sampleprep Summary:Briefly, 20 μL of serum (prepared by adding 1:20 (m/v) ultrapure water to 50 mg of feces) was filtered through a Ostro Protein Precipitation and Phospholipid Removal 96-well plate (Waters Corporation, Milford, USA), using 100 μL of cold methanol contemning the internal standard mixtures (LCA-d4, TCA-d4, GUDCA-d4, GCA-d4, CA-d4, UDCA-d4, GCDCA-d4, CDCA-d4, DCA-d4, GLCA-d4). The eluent was collected and evaporated to dryness and the residue was re-suspended in 20 μL of a 40:60 MeOH: H2O v/v mixture. The analyses were performed on an ACQUITY HSS T3 (2.1×100 mm, 1.8 μm) column, Waters (Milford), coupled to a triple quadrupole mass spectrometer (Waters Corporation, Milford, USA) with an atmospheric electrospray interface operating in negative ion mode. Separation was performed using gradient elution with 0.1 % formic acid in water (v/v) (A) and 0.1 % formic acid in acetonitrile:methanol (3:1, v/v) (B) at a flow rate of 0.5 mL/ min. Gradient program was 0 min 15 % B, 0-1 min; 30 % B, 1- 16 min; 16-18 min; 70 % B, 18–23 min 100 % B, and equilibrium time between runs was 7 min. The injection volume was 5 μL and the column was kept at 35 °C. An external calibration with nine calibration points (0.0025–600 ng/mL) was carried out for use in quantitation.

Combined analysis:

Analysis ID AN003248
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters
Column Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name ABI Sciex 5500 QTrap
Ion Mode NEGATIVE
Units ng/ml

Chromatography:

Chromatography ID:CH002393
Chromatography Summary:The analyses were performed on an ACQUITY HSS T3 (2.1×100 mm, 1.8 μm) column, Waters (Milford), coupled to a triple quadrupole mass spectrometer (Waters Corporation, Milford, USA) with an atmospheric electrospray interface operating in negative ion mode. Separation was performed using gradient elution with 0.1 % formic acid in water (v/v) (A) and 0.1 % formic acid in acetonitrile:methanol (3:1, v/v) (B) at a flow rate of 0.5 mL/ min. Gradient program was 0 min 15 % B, 0-1 min; 30 % B, 1- 16 min; 16-18 min; 70 % B, 18–23 min 100 % B, and equilibrium time between runs was 7 min. The injection volume was 5 μL and the column was kept at 35 °C.
Instrument Name:Waters
Column Name:Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um)
Column Temperature:35
Flow Gradient:0 min 15 % B, 0-1 min; 30 % B, 1- 16 min; 16-18 min; 70 % B, 18–23 min 100 % B, and equilibrium time between runs was 7 min.
Flow Rate:0.5 mL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:75% acetonitrile/25% methanol; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS003021
Analysis ID:AN003248
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:The bile acids were measured in serum and fecal sample as described based on . 20 μL of serum, using the same internal standard mixtures, was filtered through a frit filter plate (96-Well Protein Precipitation Filter Plate, Sigma Aldrich), and the effluent was collected and evaporated to dryness and the residue was dissolved in 20 μL of a 40:60 MeOH: H2O v/v mixture containing the same injection standards. Analyses were performed on an ACQUITY UPLC system coupled to a triple quadrupole mass spectrometer (Waters Corporation, Milford, USA) with an atmospheric electrospray interface operating in negative ion mode. An external calibration with six calibration points (0.5–600 ng/mL), including a solvent blank, was carried out for use in quantitation.
Ion Mode:NEGATIVE