MB Sample ID: SA201367
Local Sample ID: | 20220124-HC-112 |
Subject ID: | SU002185 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002185 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
20220124-HC-112 | SA201367 | FL024495 | Healthy | Treatment |
Collection:
Collection ID: | CO002178 |
Collection Summary: | All peripheral venous blood was collected in tube with EDTA-anticoagulant. After centrifugation the serum samples were collected and stored at -80°C before use. |
Sample Type: | Serum |
Treatment:
Treatment ID: | TR002197 |
Treatment Summary: | Three groups of serum samples were collected from Eastern Hepatobiliary Surgery Hospital including 17 healthy controls, 20 with acute hepatitis and 20 with chronic hepatitis (HBV). They were all enrolled in this study with the patients' consent and the sampling process was strictly consistent with the ethics committee of the Eastern Hepatobiliary Surgical Hospital. |
Sample Preparation:
Sampleprep ID: | SP002191 |
Sampleprep Summary: | Serum samples were mixed with 4 volumes of acetonitrile, which contains 0.001 mg/mL internal standard 4-chloro-DL-phenylalanine, to precipitate the proteins. After brief vortex mixing, the samples were incubated on ice for 15 min. The supernatants were collected after centrifuged at 20,000 g, 4 °C for 10 min, transferred to vials for LC-MS analysis. |
Combined analysis:
Analysis ID | AN003432 | AN003433 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent 1290 Infinity | Agilent 1290 Infinity |
Column | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | Triple quadrupole | Triple quadrupole |
MS instrument name | Agilent 6495 QQQ | Agilent 6495 QQQ |
Ion Mode | POSITIVE | NEGATIVE |
Units | counts | counts |
Chromatography:
Chromatography ID: | CH002537 |
Chromatography Summary: | In this study, a newly developed precision-targeted metabolomics method with a UPLC-TQ/MS system (Agilent 1290 Infnity, Agilent Technologies, USA; Agilent 6495 QQQ, Agilent Technologies, USA) in a DMRM scan-mode was applied to analyze the metabolome of interest from trial samples (serum, liver tissues and stool). Briefly, the method was performed with an ACQUITY UPLC HSS T3 column (2.1 mm i.d. × 100 mm, 1.8 μm; Waters); mobile phase A and B were water and acetonitrile with 0.1% formic acid (v/v) respectively. The flow rate was at 0.3 mL/min and the column temperature was maintained at 40 ℃. The samples were placed in an auto-sampler maintained at 4 °C with a 5 μL injection volume. The optimized gradient-elution program, as follows: 0-2 min, 98% A; 2-10 min, 98-65% A; 10-12 min, 65-20% A; 12-14 min, 20-2% A; 14-30 min, 2% A. |
Instrument Name: | Agilent 1290 Infinity |
Column Name: | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) |
Column Temperature: | 40 |
Flow Gradient: | 0-2 min, 98% A; 2-10 min, 98-65% A; 10-12 min, 65-20% A; 12-14 min, 20-2% A; 14-30 min, 2% A |
Flow Rate: | 0.3 mL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS003195 |
Analysis ID: | AN003432 |
Instrument Name: | Agilent 6495 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Agilent MassHunter Workstation Data Acquisition Agilent MassHunter |
Ion Mode: | POSITIVE |
MS ID: | MS003196 |
Analysis ID: | AN003433 |
Instrument Name: | Agilent 6495 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Agilent MassHunter Workstation Data Acquisition Agilent MassHunter |
Ion Mode: | NEGATIVE |