Return to study ST002311 main page

MB Sample ID: SA227037

Local Sample ID:45
Subject ID:SU002397
Subject Type:Bird
Subject Species:Gallus gallus
Taxonomy ID:9031

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002397
Subject Type:Bird
Subject Species:Gallus gallus
Taxonomy ID:9031

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
45SA227037FL027568SalmonellaGroup
45SA227037FL027568Week 6Moment

Collection:

Collection ID:CO002390
Collection Summary:Cecal sample were collected and immediately snap frozen for metabolomics analysis at the end of experiment
Sample Type:Cecum

Treatment:

Treatment ID:TR002409
Treatment Summary:Half of the animals in each experimental group were challenged with Salmonella Enteritidis (105 CFU/bird) at 24 h after placing. During the first 21 days of the chicken rearing period, Φ-treated group received 0.1% microencapsulated Salmonella-phage (108 PFU/g) encapsulated in Eudragit®L100 (a pH-responsive formulation) with the starter diet feed, and the control group did not receive any phage

Sample Preparation:

Sampleprep ID:SP002403
Sampleprep Summary:Cecal contents were lyophilized and homogenated. Then, 10 mg of the sample were mixed with 0.75mL of cold 75% (v/v) methanol, 0.1% (v/v) formic acid, spiked with 10μg/ml formononetin as internal standard. Then, the mix were shaked for 40’ at 20Hz using a Mixer Mill 300 (Qiagen) and centrifuged at 20,000 xg for 15 min at 4°C. The suspension (600μL) was transferred to a new 2-mL conical tube.

Combined analysis:

Analysis ID AN003775 AN003776
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Phenomenex Luna (100 x 2.1mm,2.5um) Phenomenex Luna (100 x 2.1mm,2.5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units m/z ratio m/z ratio

Chromatography:

Chromatography ID:CH002792
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Phenomenex Luna (100 x 2.1mm,2.5um)
Chromatography Type:Reversed phase

MS:

MS ID:MS003518
Analysis ID:AN003775
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z).
Ion Mode:POSITIVE
  
MS ID:MS003519
Analysis ID:AN003776
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z).
Ion Mode:NEGATIVE
  logo