Return to study ST002457 main page
MB Sample ID: SA246064
Local Sample ID: | 07_WT-10 |
Subject ID: | SU002547 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Male and female |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002547 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Male and female |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
07_WT-10 | SA246064 | FL030876 | Wild-type | Genotype |
07_WT-10 | SA246064 | FL030876 | none | Treatment |
Collection:
Collection ID: | CO002540 |
Collection Summary: | Snap-frozen kidneys were transferred into 0.5 ml homogenization tubes prefilled with 1.4mm ceramic beads (CK14, # P000933-LYSK0-A, Bertin corp) and cold (-20°C) metabolites extraction solvent (Methanol: acetonitrile: water at a ratio of 5:3:2 respectively) |
Sample Type: | Kidney |
Treatment:
Treatment ID: | TR002559 |
Treatment Summary: | A mixture of six labeled internal standards was added to the extraction solution for quality control (13C6-Glucose, 13C5-Glutamine, 13C5-Glutamate, 13C1-Alanine, 13C3-Pyruvate and 13C3-Lactate). The exact volume at each tube was adjusted according to tissue weight (average volume of 200 µl). The samples were homogenized using Precellys 24 tissue homogenizer (Bertin Technologies) precooled to 4°C (3 cycles × 30 s at 6000 rpm, with a 30 s gap between each cycle) and later centrifuged at 18,000 g for 15 min at 4°C. The supernatants were transferred into HPLC glass vials and kept at −80°C prior to LC-MS analysis. |
Sample Preparation:
Sampleprep ID: | SP002553 |
Sampleprep Summary: | The samples were homogenized using Precellys 24 tissue homogenizer (Bertin Technologies) precooled to 4°C (3 cycles × 30 s at 6000 rpm, with a 30 s gap between each cycle) and later centrifuged at 18,000 g for 15 min at 4°C. The supernatants were transferred into HPLC glass vials and kept at −80°C prior to LC-MS analysis. |
Combined analysis:
Analysis ID | AN004009 |
---|---|
Analysis type | MS |
Chromatography type | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 |
Column | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap |
Ion Mode | UNSPECIFIED |
Units | concentration |
Chromatography:
Chromatography ID: | CH002960 |
Chromatography Summary: | UPLC setup consisted a ZIC-pHILIC column (SeQuant; 150 mm × 2.1 mm, 5 μm; Merck). 5 µl of cells or kidney extracts were injected using an autosampler. Compounds were separated using a 15 minutes gradient, starting at 20% aqueous (20 mM ammonium carbonate adjusted to pH 9.2 with 0.1% of 25% ammonium hydroxide) and 80% organic (acetonitrile), terminated with 20% acetonitrile. Flow rate and column temperature were kept at 0.2 ml/min and 45°C, respectively for a total run time of 27 min |
Instrument Name: | Thermo Dionex Ultimate 3000 |
Column Name: | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) |
Column Temperature: | 45 |
Flow Gradient: | 15 min terminated with 20% acetonitrile |
Flow Rate: | 0.2 ml/min |
Solvent A: | 20% water/80% acetonitrile; 20 mM ammonium carbonate; 0.1% of 25% ammonium hydroxide (adjusted to pH 9.2) |
Solvent B: | 80%water/20% acetonitrile |
Chromatography Type: | HILIC |
MS:
MS ID: | MS003756 |
Analysis ID: | AN004009 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Briefly, Dionex Ultimate ultra-high-performance liquid chromatography (UPLC) system coupled to Orbitrap Q-Exactive mass spectrometer (Thermo Fisher Scientific) was used. The resolution was set to 35,000 at 200 mass/charge ratio (m/z) with electrospray ionization and polarity switching mode to enable both positive and negative ions across a mass range of 67–1000 m/z. |
Ion Mode: | UNSPECIFIED |