Return to study ST002486 main page
MB Sample ID: SA248772
Local Sample ID: | MB-11 |
Subject ID: | SU002576 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002576 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
MB-11 | SA248772 | FL031360 | RT+IL2v | Factor |
Collection:
Collection ID: | CO002569 |
Collection Summary: | Blood was collected at the time of sacrifice via cardiac puncture. The erythrocytes were lysed with ACK lysis buffer for 3min at RT. CD8 T cells were sorted with a CD8-negative selection Stemcell isolation kit according to manufacturer's instructions. Cells were washed with PBS at 1200RPM, 4degC for 10 mins, and cell pellets were flash frozen. |
Sample Type: | T-cells |
Treatment:
Treatment ID: | TR002588 |
Treatment Summary: | Mice were orthotopically implanted with PK5L1940 cells. Radiation therapy (8 Gy) administered 7 days post-implantation. PD1-IL2v and aCD25 dosed once per week beginning day 7 post-implantation. Blood collected at time of sacrifice. |
Sample Preparation:
Sampleprep ID: | SP002582 |
Sampleprep Summary: | Metabolites from frozen T-cell pellets were extracted with cold 5:3:2 MeOH:acetonitrile:water at a concentration of 4 million cells/mL. Samples were vortexed 30 min at 4 degrees C then supernatants clarified by centrifugation (10 min, 10,000 g, 4 degrees C) and transferred to autosampler vials. |
Processing Storage Conditions: | 4℃ |
Extract Storage: | -80℃ |
Combined analysis:
Analysis ID | AN004058 | AN004059 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Orbitrap Exploris 480 | Thermo Orbitrap Exploris 480 |
Ion Mode | NEGATIVE | POSITIVE |
Units | peak area | peak area |
Chromatography:
Chromatography ID: | CH003004 |
Chromatography Summary: | Negative C18 |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um |
Column Temperature: | 45 |
Flow Gradient: | 0-0.5 min 0% B, 0.5-1.1 min 0-100% B, 1.1-2.75 min hold at 100% B, 2.75-3 min 100-0% B, 3-5 min hold at 0% B |
Flow Rate: | 450 uL/min |
Sample Injection: | 10 uL |
Solvent A: | 95% water 5% acetonitrile 1 mM ammonium acetate |
Solvent B: | 95% acetonitrile 5% water 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH003005 |
Chromatography Summary: | Positive C18 |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 2.1 x 150 mm, 1.7 um |
Column Temperature: | 45 |
Flow Gradient: | 0-0.5 min 5% B, 0.5-1.1 min 5-95% B, 1.1-2.75 min hold at 95% B, 2.75-3 min 95-5% B, 3-5 min hold at 5% B |
Flow Rate: | 450 uL/min |
Sample Injection: | 10 uL |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS003805 |
Analysis ID: | AN004058 |
Instrument Name: | Thermo Orbitrap Exploris 480 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | We use a Thermo Orbitrap Exploris 120 (not available in the drop down box). Resolution 120,000, scan range 65-975 m/z, maximum injection time 100 ms, microscans 1, automatic gain control (AGC) detection duration 20 msec, source voltage 2.0 kV, capillary temperature 320 C, vaporizer temp 200 C, and sheath gas 50, auxiliary gas 10, and sweep gas 1 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database. |
Ion Mode: | NEGATIVE |
MS ID: | MS003806 |
Analysis ID: | AN004059 |
Instrument Name: | Thermo Orbitrap Exploris 480 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | We use a Thermo Orbitrap Exploris 120 (not available in the drop down box). Resolution 120,000, scan range 65-975 m/z, maximum injection time 100 ms, microscans 1, automatic gain control (AGC) detection duration 20 msec, source voltage 3.5 kV, capillary temperature 320 C, vaporizer temp 200 C, and sheath gas 50, auxiliary gas 10, and sweep gas 1 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database. |
Ion Mode: | POSITIVE |