Return to study ST002510 main page

MB Sample ID: SA252822

Local Sample ID:PTJ0261_2
Subject ID:SU002610
Subject Type:Bacteria
Subject Species:Eggerthella lenta
Taxonomy ID:84112
Genotype Strain:various (see sample table)

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002610
Subject Type:Bacteria
Subject Species:Eggerthella lenta
Taxonomy ID:84112
Genotype Strain:various (see sample table)

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
PTJ0261_2SA252822FL032251PTJ0261Strain
PTJ0261_2SA252822FL032251Eggerthella_lenta_DSM2243DStrain name
PTJ0261_2SA252822FL032251GLCondition
PTJ0261_2SA252822FL0322512PlateNum

Collection:

Collection ID:CO002603
Collection Summary:For the comparative strain metabolomics experiment, 96-well polypropylene deep well plates were prepared with 800μL of fresh media in each well. Starter cultures and inocula for 29 isolates of Eggerthella lenta and 1 isolate of Eggerthella sinensis [26] were prepared as described above for growth assays, except without final dilution, and 80 μL was used to inoculate wells, leaving a blank well in between every culture well to prevent cross-contamination. After 72 hours, OD600 measurements were taken, plates were centrifuged, and supernatants were collected. Plates were centrifuged at 1,928 rcf at 4°C for 8 minutes, after which supernatants were collected into fresh polypropylene tubes or plates, sealed, and flash-frozen in liquid nitrogen.
Sample Type:Bacterial culture supernatant
Collection Frequency:single time point (72 hours)
Storage Conditions:-80℃

Treatment:

Treatment ID:TR002622
Treatment Summary:For growth and metabolomics experiments, glycerol stocks of the 3 E. lenta strains were first streaked on BHI+ agar plates and incubated at 37°C for 2-3 days. Individual colonies were inoculated into 3-4 mL liquid BHI+ and incubated at 37°C for 40-48 hours, or until approximately early stationary phase. Culture optical density (600 nm wavelength absorbance, OD600) was measured using a Hach DR1900 spectrophotometer. 1 mL samples of BHI starter cultures were then centrifuged at 1,568 rcf for 4 minutes in a microcentrifuge (ThermoScientific mySpin 12) in the anaerobic chamber and resuspended in 1 mL sterile phosphate-buffered saline (PBS). The resulting suspension was vortexed and diluted to an approximate OD600 of 0.1, and used as inoculum into defined experimental conditions. Varying media conditions were prepared separately and all allowed to fully reduce in the anaerobic chamber prior to inoculation.

Sample Preparation:

Sampleprep ID:SP002616
Sampleprep Summary:Bacterial culture supernatant and sterile media, used in culture, were thawed on wet ice. Once thawed, samples were homogenized by inversion five times. Extracellular culture supernatant samples were prepared as follows: 20 μL of culture supernatant were extracted using 80 μL of a chilled extraction solvent at −20°C (1:1 acetonitrile:methanol, 5% water containing stable isotope-labeled internal standards). Samples were homogenized via pipette action, incubated for 1 hour at −20°C, centrifuged at 4°C at 6000 rcf for 5 min. The supernatant was transferred to a new plate and immediately sealed and kept at 4°C prior to prompt analysis via LC-MS/MS.

Combined analysis:

Analysis ID AN004133 AN004134
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units relative ion counts relative ion counts

Chromatography:

Chromatography ID:CH003062
Chromatography Summary:Samples, sterile media, pools, and blanks were promptly added to a Thermo Vanquish Autosampler at 4°C in a Vanquish UHPLC (Thermo Fisher Scientific, Waltham, MA). Chromatographic separation was performed using an ACQUITY Bridged Ethylene Hybrid (BEH) Amide column 2.1 x 150 mm, 1.7-micron particle size, (Waters Corp. Milford, MA), using chromatographic conditions published elsewhere (HILIC method described in the Supplementary Methods of doi.org/10.1038/s41586-021-03707-9).
Instrument Name:Thermo Vanquish
Column Name:Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:The gradient profile was held at 100% B for 2 minutes, from 100% B to 70% B in 5 minutes, holding at 70% B for 0.7 minute, from 70% B to 40% B for 1.3 minutes, holding at 40% B for 0.5 minutes, from 40% B to 30% B for 0.75 minutes, before returning to 100% B for 2.5 minutes and holding at 100% B for 4 minutes.
Flow Rate:400 μL per minute
Solvent A:100% water; 0.125% formic acid; 10 mM ammonium formate, pH 3
Solvent B:95% acetonitrile/5% water; 0.125% formic acid; 10 mM ammonium formate
Chromatography Type:HILIC

MS:

MS ID:MS003880
Analysis ID:AN004133
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Full MS-ddMS2 data was collected, an inclusion list was used to prioritize MS2 selection of metabolites from our in-house ‘local’ library, when additional scan bandwidth was available MS2 was collected in a data-dependent manner. Mass range was 60-900 mz, resolution was 60k (MS1) and 15k (MS2), centroid data was collected, loop count was 4, isolation window was 1.5 Da. Metabolomics data was processed using MS-DIAL v4.60. Features were excluded from analysis if peak height was not at least 5-fold greater in one or more samples compared to the procedural blank average.
Ion Mode:POSITIVE
  
MS ID:MS003881
Analysis ID:AN004134
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Full MS-ddMS2 data was collected, an inclusion list was used to prioritize MS2 selection of metabolites from our in-house ‘local’ library, when additional scan bandwidth was available MS2 was collected in a data-dependent manner. Mass range was 60-900 mz, resolution was 60k (MS1) and 15k (MS2), centroid data was collected, loop count was 4, isolation window was 1.5 Da. Metabolomics data was processed using MS-DIAL v4.60. Features were excluded from analysis if peak height was not at least 5-fold greater in one or more samples compared to the procedural blank average.
Ion Mode:NEGATIVE
  logo