Return to study ST002628 main page

MB Sample ID: SA261744

Local Sample ID:90251013104
Subject ID:SU002730
Subject Type:Mammal
Subject Species:Rattus norvegicus
Taxonomy ID:10116

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002730
Subject Type:Mammal
Subject Species:Rattus norvegicus
Taxonomy ID:10116

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
90251013104SA261744FL034025TrainingGroup
90251013104SA261744FL0340258 weeks of training or control timeTimepoint
90251013104SA261744FL034025FemaleSex
90251013104SA261744FL034025Rat PlasmaTissue

Collection:

Collection ID:CO002723
Collection Summary:-
Sample Type:Plasma

Treatment:

Treatment ID:TR002739
Treatment Summary:-

Sample Preparation:

Sampleprep ID:SP002736
Sampleprep Summary:Plasma samples (10 µL) were extracted using 90 µL of 74.9:24.9:0.2 (v/v/v) acetonitrile/methanol/formic acid containing stable isotope-labeled internal standards (0.2 ng/µL valine-d8, Isotec; 0.2 ng/µL phenylalanine-d8, Cambridge Isotope Laboratories). The samples were centrifuged (10 min, 9000g, 4?C) and the supernatants were transferred to autosampler vials with de-activated inserts (Waters).
Sampleprep Protocol Filename:pass1b_experimental_design_metabolomics.pdf

Combined analysis:

Analysis ID AN004300
Analysis type MS
Chromatography type HILIC
Chromatography system Shimadzu Nexera X2
Column Waters Atlantis HILIC (150 x 2.1mm,3um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units peak area

Chromatography:

Chromatography ID:CH003206
Chromatography Summary:Extracts (10 µL) were injected onto a 150 x 2.1 mm Atlantis HILIC column (Waters). The column was eluted isocratically at a flow rate of 250 µL/min with 5% mobile phase A (10 mM ammonium formate and 0.1% formic acid in water) for 1 minute followed by a linear gradient to 40% mobile phase B (acetonitrile with 0.1% formic acid) over 10 minutes
Methods Filename:pass1b_hilicpos_methods.pdf
Instrument Name:Shimadzu Nexera X2
Column Name:Waters Atlantis HILIC (150 x 2.1mm,3um)
Column Temperature:-
Flow Gradient:The column was eluted isocratically at a flow rate of 250 µL/min with 5% mobile phase A for 1 minute followed by a linear gradient to 40% mobile phase B over 10 minutes
Flow Rate:250 µL/min
Solvent A:100% water; 0.1% formic acid; 10 mM ammonium formate
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:HILIC

MS:

MS ID:MS004047
Analysis ID:AN004300
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:High resolution, accurate mass data were acquired using a system comprised of a Shimadzu Nexera X2 U-HPLC (Shimadzu Corp.; Marlborough, MA) coupled to a Q Exactive hybrid quadrupole orbitrap mass spectrometer (Thermo Fisher Scientific; Waltham, MA). MS analyses were carried out using electrospray ionization in the positive ion mode using full scan analysis over 70-800 m/z at 70,000 resolution and 3 Hz data acquisition rate. Other MS settings were: sheath gas 40, sweep gas 2, spray voltage 3.5 kV, capillary temperature 350°C, S-lens RF 40, heater temperature 300°C, microscans 1, automatic gain control target 1e6, and maximum ion time 250 ms. Raw data were processed using TraceFinder software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). The identities of 202 profiled metabolites were confirmed using reference standards.
Ion Mode:POSITIVE
  logo