MB Sample ID: SA272699

Local Sample ID:MMG-55_ABC-19126
Subject ID:SU002816
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002816
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
MMG-55_ABC-19126SA272699FL035341MaleSex
MMG-55_ABC-19126SA272699FL035341CASEDiagnosis

Collection:

Collection ID:CO002809
Collection Summary:spun inside centrifuge and processed
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR002825
Treatment Summary:NA

Sample Preparation:

Sampleprep ID:SP002822
Sampleprep Summary:SOP blood-LCGCextract-02252019

Combined analysis:

Analysis ID AN004393 AN004394
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Agilent 1290 Infinity Agilent 1290 Infinity
Column Waters ACQUITY UPLC BEH C18 (50 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (50 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units normalized peak heights normalized peak heights

Chromatography:

Chromatography ID:CH003296
Instrument Name:Agilent 1290 Infinity
Column Name:Waters ACQUITY UPLC BEH C18 (50 x 2.1mm,1.7um)
Column Temperature:45°C
Flow Gradient:0 min, 100% B; 0.5 min, 100% B; 1.95 min, 70% B; 2.55 min, 30% B; 3.15 min, 100% B; 3.8 min, 100% B
Flow Rate:0.8 mL/min
Solvent A:100% water; 10 mM ammonium formate + 0.125% formic acid, pH 3
Solvent B:95% acetonitrile/5% water; 10 mM ammonium formate; 0.125% formic acid, pH 3
Chromatography Type:HILIC

MS:

MS ID:MS004142
Analysis ID:AN004393
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:POSITIVE
  
MS ID:MS004143
Analysis ID:AN004394
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:NEGATIVE