Return to study ST002775 main page

MB Sample ID: SA295646

Local Sample ID:Left_Retina_6_NEG
Subject ID:SU002882
Subject Type:Fish
Subject Species:Danio rerio
Taxonomy ID:7955
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002882
Subject Type:Fish
Subject Species:Danio rerio
Taxonomy ID:7955
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Left_Retina_6_NEGSA295646FL035940MaleSex
Left_Retina_6_NEGSA295646FL035940UninjuredTreatment

Collection:

Collection ID:CO002875
Collection Summary:In the tissue collection process, mice were euthanized using an overdose of MS-222. The optic nerve was removed via dissection from the optic nerve head to the optic chiasm. The retinas of both female and male Zebrafish were collected and separated into biological samples. Due to the small tissue and metabolomics resolution constraints, optic nerves were pooled to generate higher signal intensities. A total of 10-11 and 12 retinas were pooled from female and male zebrafish samples, respectively. The untreated retinas were pooled using the same protocol.
Sample Type:Eye tissue

Treatment:

Treatment ID:TR002891
Treatment Summary:For optic nerve crush, animals were deeply anesthetized in 0.033% tricaine methane-sulfonate (MS-222). The right optic nerve was exposed by gently removing the connective tissue on the dorsal half of the eye and rotating the eye ventrally out of the orbit with a number 5 forceps. A nerve crush was then performed using number 5 forceps to crush the nerve ~0.5–1 mm from the optic nerve head for 5 s. Success was observed by the generation of a translucent stripe in the nerve that completely separated two areas of white myelination with no bleeding. Fish were then revived in fresh aquatic system water in individual tanks. After 1 h the tanks were returned to the fish system and animals were maintained normally with daily feeding until 3 days post injury.

Sample Preparation:

Sampleprep ID:SP002888
Sampleprep Summary:Retinas remained on dry ice to prevent metabolite degradation while the metabolite extraction was conducted. Tissues were transferred to 0.5mL Soft Tissue Lysing Kit Precellys tubes containing beads. Then, 84 µL of chilled 1:1 MeOH/H2O were added to Precellys tube. Pre-extraction internal standards were added to the tubes: 5µl of 1mg/ml Caffeine 13C6, 5µl of 1mg/ml D-Glucose 13C6, 5µl of 1mg/ml Oleic Acid 13C5, and 1µl of 5mg/mL Isoleucine 13C6 to each sample. Tissues were homogenized using Precellys 24 Touch. Cycle parameters: 2 cycles: 30 seconds homogenization at 4500 rpm, 10 seconds rest. Homogenate was transferred to a microcentrifuge tube and centrifuged at 18000xrcf for 20 min at 4°C. Then, collect supernatant and transfer pellet to Precellys Lysing Kit tube. Add 84uL of 8:1:1 Acetonitrile/Methanol/Acetone to pellet and add the rest of the pre-extraction internal standards: 5µl of 1mg/ml Caffeine 13C6, 5µl of 1mg/ml D-Glucose 13C6, 5µl of 1mg/ml Oleic Acid 13C5, 1µl of 5mg/mL Isoleucine 13C6. Final pre-extraction internal standards concentrations are 50μg/mL. Homogenization cycles were repeating using Precellys 24 Touch. Centrifuge as before and add second supernatant to first round of collected supernatant. Centrifuge at 1800xrcf for 20 min once more to remove any remaining tissue debris. Collect supernatant and dry supernatant in Speedvac. Two extraction blanks were prepared in the same manner as the biological samples. Dried samples were reconstituted immediately in 0.1% formic acid in 44.75µL of HPLC-MS grade water. Post-extraction internal standards were added: 25 µl of 5mg/ml Phenylalanine 13C6, 2.5 µl of .5mg/ml Uracil 13C 15N2, 1.25 µl of 1mg/ml Arginine 13C6, 1.25 µl of 1mg/ml Serine 13C3 to each sample.

Combined analysis:

Analysis ID AN004517 AN004518
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Thermo Accucore Amide HILIC (150 x 2.1mm, 2.6um) Thermo Accucore Amide HILIC (150 x 2.1mm, 2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Normalized Concentrations Normalized Concentrations

Chromatography:

Chromatography ID:CH003393
Chromatography Summary:Mobile Phases: NEG A: 10mM Ammonium Acetate in 95% ACN w/ .1% acetic acid NEG B: 10mM Ammonium Acetate in 50% ACN w/ .1% acetic acid POS A: 10mM Ammonium Formate in 95% ACN w/ .1% formic acid POS B: 10mM Ammonium Formate in 50% ACN w/ .1% formic acid
Instrument Name:Thermo Vanquish
Column Name:Thermo Accucore Amide HILIC (150 x 2.1mm, 2.6um)
Column Temperature:35 C
Flow Gradient:PumpModule.Pump.Pump_Pressure.AcqOn 0.000 [min] Run PumpModule.Pump.Flow.Nominal: 0.500 [ml/min] PumpModule.Pump.%B.Value: 1.0 [%] PumpModule.Pump.Curve: 5 1.000 [min] PumpModule.Pump.Flow.Nominal: 0.500 [ml/min] PumpModule.Pump.%B.Value: 1.0 [%] PumpModule.Pump.Curve: 5 9.000 [min] PumpModule.Pump.Flow.Nominal: 0.500 [ml/min] PumpModule.Pump.%B.Value: 95.0 [%] PumpModule.Pump.Curve: 5 10.000 [min] PumpModule.Pump.Flow.Nominal: 0.500 [ml/min] PumpModule.Pump.%B.Value: 95.0 [%] PumpModule.Pump.Curve: 5 10.500 [min] PumpModule.Pump.Flow.Nominal: 0.500 [ml/min] PumpModule.Pump.%B.Value: 1.0 [%] PumpModule.Pump.Curve: 5 15.000 [min] PumpModule.Pump.Flow.Nominal: 0.500 [ml/min] PumpModule.Pump.%B.Value: 1.0 [%] PumpModule.Pump.Curve: 5 15.000 [min] Stop Run
Flow Rate:0.5 ml/min
Solvent A:95% acetonitrile/5% water; 10mM Ammonium Formate; 0.1% formic acid
Solvent B:50% acetonitrile/50% water; 10mM Ammonium Formate; 0.1% formic acid
Chromatography Type:HILIC

MS:

MS ID:MS004264
Analysis ID:AN004517
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The samples were run using a Q ExactiveTM mass spectrometer coupled to a heated electrospray ionization (HESI) source. The spray voltage was set to 3.50 kV, capillary temperature to 350°C, sheath gas to 55, aux gas to 14, sweep gas to 4, and S-Lens RF Level to 30.0. The mass range was set to 67 – 1000 m/z, resolution 140,000 for full scan and 35,000 for ddMS2. AGC target was set to 1e6 for full scan and 2e5 for ddMS2. The max injection time (IT) was 100 seconds for full scan mode and 50 seconds for ddMS2. The number of microscans was 2, and normalized collision energy (NCE) was set to 20, 35, and 50. Samples were run in both positive and negative ion mode separately. The parameters for negative mode were the same except the spray voltage, which was set to 2.50 kV and capillary temperature to 380°C. Metabolites were identified from their Thermo.RAW scans using Compound DiscovererTM 3.3 software. Extraction blanks were used to determine and correct for reagent effects, allow for the creation of exclusions lists, mark background components, and filters the background components from the results table in Compound DiscovererTM 3.3. Pooled QCs were used for initial compound normalization and identification. All non-identified compounds were removed.
Ion Mode:POSITIVE
  
MS ID:MS004265
Analysis ID:AN004518
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The samples were run using a Q ExactiveTM mass spectrometer coupled to a heated electrospray ionization (HESI) source. The spray voltage was set to 3.50 kV, capillary temperature to 350°C, sheath gas to 55, aux gas to 14, sweep gas to 4, and S-Lens RF Level to 30.0. The mass range was set to 67 – 1000 m/z, resolution 140,000 for full scan and 35,000 for ddMS2. AGC target was set to 1e6 for full scan and 2e5 for ddMS2. The max injection time (IT) was 100 seconds for full scan mode and 50 seconds for ddMS2. The number of microscans was 2, and normalized collision energy (NCE) was set to 20, 35, and 50. Samples were run in both positive and negative ion mode separately. The parameters for negative mode were the same except the spray voltage, which was set to 2.50 kV and capillary temperature to 380°C. Metabolites were identified from their Thermo.RAW scans using Compound DiscovererTM 3.3 software. Extraction blanks were used to determine and correct for reagent effects, allow for the creation of exclusions lists, mark background components, and filters the background components from the results table in Compound DiscovererTM 3.3. Pooled QCs were used for initial compound normalization and identification. All non-identified compounds were removed.
Ion Mode:NEGATIVE