MB Sample ID: SA302610

Local Sample ID:MtdBlank004
Subject ID:SU002926
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002926
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
MtdBlank004SA302610FL036645Method BlankTreatment

Collection:

Collection ID:CO002919
Collection Summary:Excision while the heart still beating and flash freeze within 15 seconds of excision
Sample Type:Heart

Treatment:

Treatment ID:TR002935
Treatment Summary:Saline IP and heparine SC injection in control & mutant group. After 10 minutes of saline injection we performed cervical dislocation, whole heart excision and flash freeze within 15 seconds of excision.

Sample Preparation:

Sampleprep ID:SP002932
Sampleprep Summary:2 mg of lyophilized tissue extracted with 225 uL MeOH + 188 uL H2O + 750 uL MTBE. 350 uL of the organic layer was dried and resuspended 90:10 MeOH + Toluene with internal standards.

Combined analysis:

Analysis ID AN004584 AN004585 AN004586
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290 Waters Acquity
Column Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI ESI
MS instrument type QTOF QTOF Orbitrap
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE
Units peak heights peak heights raw area counts rescaled to set the median equal to 1

Chromatography:

Chromatography ID:CH003445
Chromatography Summary:-
Instrument Name:Agilent 1290
Column Name:Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um)
Column Temperature:65C
Flow Gradient:0 min 15% (B), 0–2 min 30% (B), 2–2.5 min 48% (B), 2.5–11 min 82% (B), 11–11.5 min 99% (B), 11.5– 12 min 99% (B), 12–12.1 min 15% (B), 12.1–15 min 15% (B)
Flow Rate:0.6 mL/min
Solvent A:60:40 v/v acetonitrile:water + 10 mM ammonium formate + 0.1% formic acid
Solvent B:90:10 v/v isopropanol:acetonitrile + 10 mM ammonium formate + 0.1% formic acid
Chromatography Type:Reversed phase
  
Chromatography ID:CH003446
Chromatography Summary:Low pH polar (LC/MS Pos early)
Instrument Name:Waters Acquity
Column Name:Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
Column Temperature:-
Flow Gradient:-
Flow Rate:-
Solvent A:-
Solvent B:-
Chromatography Type:Reversed phase

MS:

MS ID:MS004330
Analysis ID:AN004584
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:POSITIVE
  
MS ID:MS004331
Analysis ID:AN004585
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:NEGATIVE
  
MS ID:MS004332
Analysis ID:AN004586
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos early)
Ion Mode:POSITIVE