MB Sample ID: SA313082

Local Sample ID:PP_D2
Subject ID:SU002981
Subject Type:Water sample

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002981
Subject Type:Water sample

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
PP_D2SA313082FL037408DTreatment

Collection:

Collection ID:CO002974
Collection Summary:Bacteria was grown in the medium containing CTAB. The water sample was collected with a syringe and filtered for storage.
Sample Type:Bacterial cells

Treatment:

Treatment ID:TR002990
Treatment Summary:Reactors are set under different conditions: composite membrane (MR) or polypropylene membrane (PP). The biofilms were treated under different conditions: A: with "160mg/L CTAB + 3g/L NH4+, low O2 pressure", B: "160mg/L CTAB + 3g/L NH4+, high O2 pressure", C:" 160mg/L CTAB, high O2 pressure", D:"400mg/L CTAB, high O2 pressure".

Sample Preparation:

Sampleprep ID:SP002987
Sampleprep Summary:Liquid samples were filtered and stored in refrigerator before assay. Each sample was injected twice: 10 µL for analysis using negative ionization mode and 4 µL for analysis using positive ionization mode

Combined analysis:

Analysis ID AN004702 AN004703
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Agilent 1290 Agilent 1290
Column Waters XBridge BEH Amide (150 x 2.1 mm, 2.5um) Waters XBridge BEH Amide (150 x 2.1 mm, 2.5um)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name Agilent 6490 QQQ Agilent 6490 QQQ
Ion Mode POSITIVE NEGATIVE
Units counts per second counts per second

Chromatography:

Chromatography ID:CH003541
Chromatography Summary:LC-MS/MS platform (Agilent 1290 UPLC-6490 QQQ-MS)
Instrument Name:Agilent 1290
Column Name:Waters XBridge BEH Amide (150 x 2.1 mm, 2.5um)
Column Temperature:40
Flow Gradient:After the initial 1-min isocratic elution of 90% B, the percentage of Solvent B was gradually decreased to 40% at t = 11 min. The composition of Solvent B was maintained at 40% for 4 min (t=15 min), and then the percentage of B gradually went back to 90%, to prepare for the next injection.
Flow Rate:0.3 mL/min
Solvent A:10 mM ammonium acetate, 10 mM ammonium hydroxide in 95% H2O/5% acetonitrile
Solvent B:10 mM ammonium acetate, 10 mM ammonium hydroxide in 95% acetonitrile/5% H2O
Chromatography Type:HILIC

MS:

MS ID:MS004448
Analysis ID:AN004702
Instrument Name:Agilent 6490 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:LC-MS/MS
Ion Mode:POSITIVE
  
MS ID:MS004449
Analysis ID:AN004703
Instrument Name:Agilent 6490 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:LC-MS/MS
Ion Mode:NEGATIVE