Return to study ST002872 main page

MB Sample ID: SA313923

Local Sample ID:KOFemale_1059
Subject ID:SU002985
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002985
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
KOFemale_1059SA313923FL037429KIKOGenotype
KOFemale_1059SA313923FL037429KIKO_700 FTreatment

Collection:

Collection ID:CO002978
Collection Summary:Mice were anesthetized with pentobarbital. Hearts were extracted, washed in PBS and snap frozen in liquid nitrogen.
Sample Type:Heart

Treatment:

Treatment ID:TR002994
Treatment Summary:N/A

Sample Preparation:

Sampleprep ID:SP002991
Sampleprep Summary:15 mg of cardiac tissue was homogenized in 80% methanol (Sigma) using Tissue Tearer (BioSpec) on dry ice. Samples were incubated at -80ºC for 4 hours. Homogenates were then centrifuged at 14,000 rfc for 20 min at 4ºC. The supernatant was extracted and stored at -80ºC for mass spectroscopy (Weill Cornell Medicine Meyer Cancer Center Proteomics & Metabolomics Core Facility). Peak intensities for metabolites were screened for missing values and analyzed by using MetaboAnalyst software (version 5.0).

Combined analysis:

Analysis ID AN004708
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Vanquish
Column SeQuant ZIC-pHILIC (150 x 2.1mm, 5um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units Peak intensity

Chromatography:

Chromatography ID:CH003545
Instrument Name:Thermo Vanquish
Column Name:SeQuant ZIC-pHILIC (150 x 2.1mm, 5um)
Column Temperature:30
Flow Gradient:85% to 30% acetonitrile (ACN)
Flow Rate:150 μL/min
Solvent A:0.1% NH4OH/20 mM CH3COONH4
Solvent B:100% acetonitrile
Chromatography Type:HILIC

MS:

MS ID:MS004454
Analysis ID:AN004708
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS acquisition Comments: The Q Exactive was operated in full scan, polarity-switching mode with the following parameters: the spray voltage 3.0 kV, the heated capillary temperature 300 °C, the HESI probe temperature 350 °C, the sheath gas flow 40 units, the auxiliary gas flow 15 units. MS data acquisition was performed in the m/z range of 70–1,000, with 70,000 resolution (at 200 m/z). Data processing Comments: The MS data was processed using XCalibur 4.1 (Thermo Scientific) to extract the metabolite signal intensity for relative quantitation. Metabolites were identified using an in-house library established using chemical standards. Identification required exact mass (within 5ppm) and standard retention times. Software/procedures used for feature assignments: The MS data was processed using XCalibur 4.1 (Thermo Scientific) to extract the metabolite signal intensity for relative quantitation. Metabolites were identified using an in-house library established using chemical standards. Identification required exact mass (within 5ppm) and standard retention times.
Ion Mode:POSITIVE
  logo