Return to study ST002977 main page

MB Sample ID: SA323289

Local Sample ID:HILIC_R8_Pre_FMT_Neg
Subject ID:SU003090
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:61.1 +/- 15.2
Gender:Male and female
Human Lifestyle Factors:Unsuccessful antibiotic treatment for recurrent C.difficile infection
Human Medications:Vancomycin, Metronidazole, Fidaxomicin, probiotic

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003090
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:61.1 +/- 15.2
Gender:Male and female
Human Lifestyle Factors:Unsuccessful antibiotic treatment for recurrent C.difficile infection
Human Medications:Vancomycin, Metronidazole, Fidaxomicin, probiotic

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
HILIC_R8_Pre_FMT_NegSA323289FL0386220.5xConcentration
HILIC_R8_Pre_FMT_NegSA323289FL038622PreFMT
HILIC_R8_Pre_FMT_NegSA323289FL038622Fecal matterSample type

Collection:

Collection ID:CO003083
Collection Summary:All participants were enrolled under IRB #16-2283 at the University of North Carolina Hospital. Fecal samples were collected pre-FMT and six months post-FMT for eight patients with prior unsuccessful antibiotic treatment for C. diff. infection. Fecal samples were aliquoted into Eppendorf tubes and stored at -80 ºC until extraction.
Sample Type:Feces
Collection Method:Colonic flush
Storage Conditions:-80℃

Treatment:

Treatment ID:TR003099
Treatment Summary:Fecal samples were collected pre-FMT and six months post-FMT for eight patients with prior unsuccessful antibiotic treatment for C. diff. infection. Participants had received previous therapies including metronidazole, vancomycin short course, vancomycin taper, fidaxomicin, or a probiotic prior to FMT.
Treatment:Fecal microbiota transplant (FMT)

Sample Preparation:

Sampleprep ID:SP003096
Sampleprep Summary:Fecal samples were weighed into pre-tared 2 mL Precellys (Bertin Corp.) compatible vials, and one 2.8 mm stainless steel bead was added to aid homogenization. Fecal matter was homogenized using a Precellys Evolution by two 20 s cycles separated by a 30 s break. Extraction solvent was used at a ratio of 1 mL per 5 g feces and was comprised of 1:1:1 methanol:acetonitrile:acetone containing 10 uM of D3-creatine, D10-isoleucine, D2-biotin, D5-tryptophan, D3-caffeine, D3-octanoylcarnitine, D3-palmitoylcarnitine, D4-deoxycholic acid, D4-cholic acid, and D7-arginine as internal standards. Following extraction, samples were centrifuged for 10 min at 17,000 rpm. 100 uL aliquots of supernatant were transferred to Eppendorf vials, dried under a gentle stream of nitrogen, and stored at -80 ºC. On the day of analysis, the dried extracts were reconstituted in 85:15 acetonitrile:water for HILIC analysis or 9:1 water:methanol for RPLC analysis with volumes as described below. Pooled samples were prepared by combining equal volumes of reconstituted fecal matter extracts from all subjects.
Processing Storage Conditions:On ice
Extraction Method:1 g feces / 5 mL of 1:1:1 methanol:acetonitirle:acetone
Extract Storage:4℃
Sample Resuspension:9:1 Water:Methanol for Reversed phase - CSH; 85:15 acetonitrile:water for HILIC

Combined analysis:

Analysis ID AN004887 AN004888 AN004889 AN004890
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

Chromatography:

Chromatography ID:CH003688
Chromatography Summary:Individual subject samples, fractionated and unfractionated pooled samples, and analytical standards were analyzed by HILIC (Waters BEH Amide, 2.1 x 100 mm, 1.7 um) and RPLC at high pH (Waters Charged-Surface Hybrid [CSH] C18, 2.1 x 100 mm, 1.7 um) in both positive and negative ion modes on a Thermo Vanquish Horizon LC coupled to an Orbitrap ID-X mass spectrometer. For HILIC separations, mobile phase A consisted of 95:5 water:acetonitrile with 10 mM ammonium formate plus 0.125 % v/v formic acid and mobile phase B was 5:95 water:acetonitrile with the same additive concentrations. HILIC separations utilized the following gradient: 0 min, 100% B; 0-0.5 min 100% B; 0.5-7 min 85% B; 7-9 min 85% B; 9-16 min 50% B; 16-16.1 min 100% B; 16.1-20 min 100% B. For CSH separations, mobile phase A consisted of water with 10 mM ammonium acetate plus 0.025% ammonium hydroxide (v/v) and mobile phase B was methanol with the same additives
Instrument Name:Thermo Vanquish
Column Name:Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
Column Temperature:55
Flow Gradient:0 min, 100% B; 0-0.5 min 100% B; 0.5-7 min 85% B; 7-9 min 85% B; 9-16 min 50% B; 16-16.1 min 100% B; 16.1-20 min 100% B
Flow Rate:0.3 mL/min
Solvent A:95%water/5% acetonitrile; 10 mM ammonium formate; 0.125 % v/v formic acid
Solvent B:5% water/95% acetonitrile; 10 mM ammonium formate; 0.125 % v/v formic acid
Washing Buffer:9:1 water:methanol
Chromatography Type:HILIC
  
Chromatography ID:CH003689
Chromatography Summary:Individual subject samples, fractionated and unfractionated pooled samples, and analytical standards were analyzed by HILIC (Waters BEH Amide, 2.1 x 100 mm, 1.7 um) and RPLC at high pH (Waters Charged-Surface Hybrid [CSH] C18, 2.1 x 100 mm, 1.7 um) in both positive and negative ion modes on a Thermo Vanquish Horizon LC coupled to an Orbitrap ID-X mass spectrometer. For CSH separations, mobile phase A consisted of water with 10 mM ammonium acetate plus 0.025% ammonium hydroxide (v/v) and mobile phase B was methanol with the same additives. CSH separations utilized the following gradient: 0 min 0% B, 0-5 min 60% B; 5-13 min 99% B; 13-17 min 99% B; 17-17.1 min 0% B; 17-20 min 0% B.
Instrument Name:Thermo Vanquish
Column Name:Waters ACQUITY UPLC CSH C18 (100 x 2.1mm,1.7um)
Column Temperature:55
Flow Gradient:0 min 0% B, 0-5 min 60% B; 5-13 min 99% B; 13-17 min 99% B; 17-17.1 min 0% B; 17-20 min 0% B
Flow Rate:0.45 mL/min
Solvent A:100% water; 10 mM ammonium acetate; 0.025% ammonium hydroxide (v/v)
Solvent B:100% methanol; 10 mM ammonium acetate; 0.025% ammonium hydroxide (v/v)
Washing Buffer:85:15 acetonitrile:water
Chromatography Type:Reversed phase

MS:

MS ID:MS004631
Analysis ID:AN004887
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometer settings were as follows: sheath gas, 40; aux gas, 10; sweep gas, 1; ion transfer tube temp, 325 ºC; vaporizer temp, 300 ºC; orbitrap resolution. 120000; scan range, 70-800 m/z; RF lens, 45%; normalized AGC target, 25%; maximum injection time, auto; microscans, 1; data type, profile; internal mass calibration, EASY-ICTM. Positive ion spray voltage was set to 3200 V. Instrument settings for MS1 and MS/MS methods were identical, except orbitrap resolution was decreased to maximize MS/MS spectra collection. The data-dependent MS/MS methods utilized the following settings: full scan orbitrap resolution, 60000; intensity threshold, 1.0x104; dynamic exclusion properties; exclusion duration 3 seconds (exclude after 1 time with +/- 5 ppm); isolation mode, quadrupole; isolation window, 1.2 m/z; activation type, HCD; collision energy mode, assisted; collision energies, 20, 40, and 80%; detector type, orbitrap; orbitrap resolution, 30000; normalized AGC target, 20%; maximum injection time, 54 ms; microscans, 1; data type, centroid; cycle time, 1.2 s.
Ion Mode:POSITIVE
Capillary Temperature:325
Collision Energy:20, 40, 80
Collision Gas:N2
Dry Gas Flow:Sheath: 40, Aux: 10, Sweep: 1
Fragmentation Method:Assisted
Ion Source Temperature:300
Ion Spray Voltage:+3200
Ionization:Positive
Mass Accuracy:120,000
Automatic Gain Control:45%
  
MS ID:MS004632
Analysis ID:AN004888
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometer settings were as follows: sheath gas, 40; aux gas, 10; sweep gas, 1; ion transfer tube temp, 325 ºC; vaporizer temp, 300 ºC; orbitrap resolution. 120000; scan range, 70-800 m/z; RF lens, 45%; normalized AGC target, 25%; maximum injection time, auto; microscans, 1; data type, profile; internal mass calibration, EASY-ICTM. Positive ion spray voltage was set to -3200 V. Instrument settings for MS1 and MS/MS methods were identical, except orbitrap resolution was decreased to maximize MS/MS spectra collection. The data-dependent MS/MS methods utilized the following settings: full scan orbitrap resolution, 60000; intensity threshold, 1.0x104; dynamic exclusion properties; exclusion duration 3 seconds (exclude after 1 time with +/- 5 ppm); isolation mode, quadrupole; isolation window, 1.2 m/z; activation type, HCD; collision energy mode, assisted; collision energies, 20, 40, and 80%; detector type, orbitrap; orbitrap resolution, 30000; normalized AGC target, 20%; maximum injection time, 54 ms; microscans, 1; data type, centroid; cycle time, 1.2 s.
Ion Mode:NEGATIVE
Capillary Temperature:325
Collision Energy:20, 40, 80
Collision Gas:N2
Dry Gas Flow:Sheath: 40, Aux: 10, Sweep: 1
Fragmentation Method:Assisted
Ion Source Temperature:300
Ion Spray Voltage:-3200
Ionization:Negative
Mass Accuracy:120,000
Automatic Gain Control:45%
  
MS ID:MS004633
Analysis ID:AN004889
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometer settings were as follows: sheath gas, 40; aux gas, 10; sweep gas, 1; ion transfer tube temp, 325 ºC; vaporizer temp, 300 ºC; orbitrap resolution. 120000; scan range, 70-800 m/z; RF lens, 45%; normalized AGC target, 25%; maximum injection time, auto; microscans, 1; data type, profile; internal mass calibration, EASY-ICTM. Positive ion spray voltage was set to 3200 V. Instrument settings for MS1 and MS/MS methods were identical, except orbitrap resolution was decreased to maximize MS/MS spectra collection. The data-dependent MS/MS methods utilized the following settings: full scan orbitrap resolution, 60000; intensity threshold, 1.0x104; dynamic exclusion properties; exclusion duration 3 seconds (exclude after 1 time with +/- 5 ppm); isolation mode, quadrupole; isolation window, 1.2 m/z; activation type, HCD; collision energy mode, assisted; collision energies, 20, 40, and 80%; detector type, orbitrap; orbitrap resolution, 30000; normalized AGC target, 20%; maximum injection time, 54 ms; microscans, 1; data type, centroid; cycle time, 1.2 s.
Ion Mode:POSITIVE
Capillary Temperature:325
Collision Energy:20, 40, 80
Collision Gas:N2
Dry Gas Flow:Sheath: 40, Aux: 10, Sweep: 1
Fragmentation Method:Assisted
Ion Source Temperature:300
Ion Spray Voltage:+3200
Ionization:Positive
Mass Accuracy:120,000
Automatic Gain Control:45%
  
MS ID:MS004634
Analysis ID:AN004890
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Mass spectrometer settings were as follows: sheath gas, 40; aux gas, 10; sweep gas, 1; ion transfer tube temp, 325 ºC; vaporizer temp, 300 ºC; orbitrap resolution. 120000; scan range, 70-800 m/z; RF lens, 45%; normalized AGC target, 25%; maximum injection time, auto; microscans, 1; data type, profile; internal mass calibration, EASY-ICTM. Positive ion spray voltage was set to -3200 V. Instrument settings for MS1 and MS/MS methods were identical, except orbitrap resolution was decreased to maximize MS/MS spectra collection. The data-dependent MS/MS methods utilized the following settings: full scan orbitrap resolution, 60000; intensity threshold, 1.0x104; dynamic exclusion properties; exclusion duration 3 seconds (exclude after 1 time with +/- 5 ppm); isolation mode, quadrupole; isolation window, 1.2 m/z; activation type, HCD; collision energy mode, assisted; collision energies, 20, 40, and 80%; detector type, orbitrap; orbitrap resolution, 30000; normalized AGC target, 20%; maximum injection time, 54 ms; microscans, 1; data type, centroid; cycle time, 1.2 s.
Ion Mode:NEGATIVE
Capillary Temperature:325
Collision Energy:20, 40, 80
Collision Gas:N2
Dry Gas Flow:Sheath: 40, Aux: 10, Sweep: 1
Fragmentation Method:Assisted
Ion Source Temperature:300
Ion Spray Voltage:+3200
Ionization:Negative
Mass Accuracy:120,000
Automatic Gain Control:45%