Return to study ST002994 main page

MB Sample ID: SA326022

Local Sample ID:9992_Diagnosis_Con
Subject ID:SU003107
Subject Type:Mammal
Subject Species:Bos taurus
Taxonomy ID:9913
Gender:Female
Animal Housing:Free-stalls
Animal Feed:TMR

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003107
Subject Type:Mammal
Subject Species:Bos taurus
Taxonomy ID:9913
Gender:Female
Animal Housing:Free-stalls
Animal Feed:TMR

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
9992_Diagnosis_ConSA326022FL038761ConGroup
9992_Diagnosis_ConSA326022FL038761DiagnosisTime
9992_Diagnosis_ConSA326022FL038761MultParity

Collection:

Collection ID:CO003100
Collection Summary:All cows had uterine fluid collected at calving (first 24h after calving), and at diagnosis (day of metritis diagnosis). Briefly, cows’ cervix was stabilized by rectal palpation, the vulva was rinsed with alcohol 70% and dried with paper towels. Subsequently, a single-use plastic round-tip pipette (UterFlush pipettes, Van Beek) was introduced into the vagina at a 45° angle and manipulated through the cervix. A total of 50 mL of sterile saline solution (0.9% sodium chloride irrigation, Baxter) was infused into the uterine lumen using a 60-mL syringe (Covidien) attached to the end of the pipette. Uterine contents were homogenized, retrieved into the same 60-mL syringe, and transferred to a sterile 15-mL conical tube (VWR). After collection, tubes were placed on ice and transported to the laboratory within 2 hours. Once in the laboratory, uterine fluid samples were aliquoted into 2-mL microcentrifuge tubes (Eppendorf) and stored at -80 oC until essayed. One frozen uterine fluid aliquot was submitted to the University of California’s West Coast Metabolomics Center in Davis, CA for metabolome analysis.
Sample Type:Uterine fluid

Treatment:

Treatment ID:TR003116
Treatment Summary:This was a case-control study, hence, there were not treatments applied. Cows were self-assigned to the groups. Cows that developed metritis were paired with healthy cows by days in milk.

Sample Preparation:

Sampleprep ID:SP003113
Sampleprep Summary:Uterine fluid samples were aliquoted into 2-mL microcentrifuge tubes (Eppendorf) and stored at -80 oC until essayed.

Combined analysis:

Analysis ID AN004918
Analysis type MS
Chromatography type GC
Chromatography system Leco Pegasus IV GC
Column Restek Rtx-5Sil MS (30m x 0.25mm, 0.25um)
MS Type EI
MS instrument type GC-TOF
MS instrument name Leco Pegasus IV TOF
Ion Mode POSITIVE
Units peak heights

Chromatography:

Chromatography ID:CH003713
Instrument Name:Leco Pegasus IV GC
Column Name:Restek Rtx-5Sil MS (30m x 0.25mm, 0.25um)
Column Temperature:50-330
Flow Gradient:.
Flow Rate:1 mL min-1
Solvent A:.
Solvent B:.
Chromatography Type:GC

MS:

MS ID:MS004661
Analysis ID:AN004918
Instrument Name:Leco Pegasus IV TOF
Instrument Type:GC-TOF
MS Type:EI
MS Comments:Data are acquired using the following chromatographic parameters, with more details to be found in Fiehn O. et al. Plant J. 53 (2008) 691–704. Column: Restek corporation Rtx-5Sil MS (30 m length x 0.25 mm internal diameter with 0.25 μm film made of 95% dimethyl/5%diphenylpolysiloxane) Mobile phase: Helium Column temperature: 50-330°C Flow- rate: 1 mL min-1 Injection volume: 0.5 μL Injection: 25 splitless time into a multi-baffled glass liner Injection temperature: 50°C ramped to 250°C by 12°C s-1 Oven temperature program: 50°C for 1 min, then ramped at 20°C min-1 to 330°C, held constant for 5 min. The analytical GC column is protected by a 10 m long empty guard column which is cut by 20 cm intervals whenever the reference mixture QC samples indicate problems caused by column contaminations. We have validated that at this sequence of column cuts, no detrimental effects are detected with respect to peak shapes, absolute or relative metabolite retention times or reproducibility of quantifications. This chromatography method yields excellent retention and separation of primary metabolite classes (amino acids, hydroxyl acids, carbohydrates, sugar acids, sterols, aromatics, nucleosides, amines and miscellaneous compounds) with narrow peak widths of 2–3 s and very good within-series retention time reproducibility of better than 0.2 s absolute deviation of retention times. We use automatic liner exchanges after each set of 10 injections which we could show to reduce sample carryover for highly lipophilic compounds such as free fatty acids. Mass spectrometry parameters are used as follows: a Leco Pegasus IV mass spectrometer is used with unit mass resolution at 17 spectra s-1 from 80-500 Da at - 70 eV ionization energy and 1800 V detector voltage with a 230°C transfer line and a 250°C ion source.
Ion Mode:POSITIVE