Summary of Study ST000437

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000337. The data can be accessed directly via it's Project DOI: 10.21228/M8S896 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)
Study IDST000437
Study TitleMetabolomic analysis of human plasma samples spiked with unknown chemicals
Study TypeUntargeted metabolomics for sample classification
Study SummaryTo conduct metabolomic studies comparing 20 males and 20 females as well as 10 pool controls and 5 spike-in samples using MS platform to perform both qualitative and quantitative metabolome analysis to classify the sample groups (male, female, pooled) and to identify the spiked-in compounds.
Institute
University of Minnesota
DepartmentDepartment of Food Science and Nutrition
LaboratoryNutritional Metabolomics
Last NameChen
First NameChi
Address1334 Eckles Ave W, St Paul, MN 55108
Emailchichen@umn.edu
Phone612-624-7704
Submit Date2016-06-29
Num Groups4
Total Subjects55
Num Males20
Num Females20
Raw Data AvailableYes
Raw Data File Type(s)raw(Waters)
Chear StudyYes
Analysis Type DetailLC-MS
Release Date2024-12-31
Release Version1
Chi Chen Chi Chen
https://dx.doi.org/10.21228/M8S896
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000687 AN000688
Chromatography ID CH000499 CH000500
MS ID MS000613 MS000614
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Waters Acquity Waters Acquity
Column Waters Acquity UPLC BEH amide,(100 x 2.1mm,1.7um,100 Å) Waters ACQUITY UPLC BEH C8
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Waters Xevo-G2-S Waters Xevo-G2-S
Ion Mode POSITIVE POSITIVE
Units peak area nM