Return to study ST000882 main page

MB Sample ID: SA051167

Local Sample ID:S8
Subject ID:SU000916
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:13 - 66
Gender:Female and Male
Human Inclusion Criteria:Retrospective serum samples from leprosy patients diagnosed or not with type 1 reaction that were not receiving multidrug therapy or corticosteroid therapy at the time of blood collection.
Human Exclusion Criteria:Retrospective serum samples from leprosy patients that were under multidrug therapy and/or corticosteroid therapy at the time of blood collection were excluded from the study.
Subject Comments:The patients exhibited borderline tuberculoid, borderline borderline and borderline lepromatous forms of leprosy and was diagnosed or not with type 1 reaction.

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001438 AN001439
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290
Column Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um) Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um)
MS Type ESI ESI
MS instrument type TOF TOF
MS instrument name Agilent 6224 TOF Agilent 6224 TOF
Ion Mode NEGATIVE POSITIVE
Units Peak area Peak area

Chromatography:

Chromatography ID:CH001009
Chromatography Summary:This was used for negative mode. The solvent gradient used for all chromatography was 2% solvent B for 3 min followed by a 15 min linear gradient of 2% to 98% solvent B, which was held for 0.3 min. Then returned to starting conditions over 1.2 min. Triplicate LC-MS injections were made of each sample and the order of sample injection (including triplicates) was randomized.
Instrument Name:Agilent 1290
Column Name:Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um)
Column Temperature:50C
Flow Gradient:0.25 mL/min
Flow Rate:0.25 mL/min
Injection Temperature:4C
Sample Injection:20uL
Solvent A:89% water/5% acetonitrile/5% isopropanol; 5 mM ammonium acetate
Solvent B:50% acetonitrile/50% isopropanol; 5 mM ammonium acetate
Capillary Voltage:2.8 kV
Chromatography Type:Reversed phase
  
Chromatography ID:CH001010
Chromatography Summary:This was used for positive mode. The solvent gradient used for all chromatography was 2% solvent B for 3 min followed by a 15 min linear gradient of 2% to 98% solvent B, which was held for 0.3 min. Then returned to starting conditions over 1.2 min. Triplicate LC-MS injections were made of each sample and the order of sample injection (including triplicates) was randomized.
Instrument Name:Agilent 1290
Column Name:Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um)
Column Temperature:50C
Flow Gradient:0.25 mL/min
Flow Rate:0.25 mL/min
Injection Temperature:4C
Sample Injection:20uL
Solvent A:95% water/5% acetonitrile; 0.1% formic acid
Solvent B:95% acetonitrile/5% water; 0.1% formic acid
Capillary Voltage:4.0kV
Chromatography Type:Reversed phase
  logo