Return to study ST002378 main page
MB Sample ID: SA237423
Local Sample ID: | WT-JX-3 |
Subject ID: | SU002467 |
Subject Type: | Cultured cells |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Male and female |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003875 | AN003876 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Ion pair | Unspecified |
Chromatography system | Shimadzu Nexera X2 | Shimadzu Nexera X2 |
Column | Agilent Zorbax Eclipse Plus C18 (100 x 2.1mm, 1.8 um) | Restek Ultra PFPP (150 x 2.1mm,3um) |
MS Type | ESI | ESI |
MS instrument type | Triple quadrupole | Triple quadrupole |
MS instrument name | Shimadzu Nexera X2 | Shimadzu Nexera X2 |
Ion Mode | NEGATIVE | NEGATIVE |
Units | Peak area ratio | Peak area ratio |
Chromatography:
Chromatography ID: | CH002871 |
Chromatography Summary: | 500 μL of cell extract and 20 μL of MES (Thermo Fisher Scientific, Waltham, MA, USA) internal standard solution (10 ng/μL) were combined and mixed thoroughly through vortexing. The mixture was then dried under vacuum and reconstituted for analysis in 100 μL of ultrapure water (Optima, Thermo Fisher Scientific, Waltham, MA, USA). The analysis was performed on a Shimadzu Nexera UHPLC system coupled with a Shimadzu LCMS-8050 triple-quadrupole mass spectrometer (Kyoto, Japan). Two LC-MS/MS methods were employed to measure the targets. Ion-Pairing Separation was performed at 0.3 ml/min on a Zorbax Eclipse Plus C18 column (1.8 μm, 2.1 x 100 mm; Agilent, Santa Clara, CA USA). Mobile phase A consisted of ultrapure water (Optima, Thermo Fisher Scientific, Waltham, MA, USA) with 10 mM ammonium acetate (J.T. Baker, Thermo Fisher Scientific, Waltham, MA, USA) and 10 mM tributylamine (Acros Organics, Thermo Fisher Scientific, Fair Lawn NJ, USA) and mobile phase B consisted of methanol (Optima, Thermo Fisher Scientific, Waltham, MA, USA). The separation used the following gradient profile: 2 minutes at 0% B, a ramp to 25% B at 8 minutes, another ramp to 98%B at 12 minutes, a 3 minute hold until 15 minutes, and then a drop back to 0% B at 15.1 minutes and allowed to equilibrate there until 25 minutes. All analytes were monitored in negative mode. |
Instrument Name: | Shimadzu Nexera X2 |
Column Name: | Agilent Zorbax Eclipse Plus C18 (100 x 2.1mm, 1.8 um) |
Flow Gradient: | The separation used the following gradient profile: 2 minutes at 0% B, a ramp to 25% B at 8 minutes, another ramp to 98%B at 12 minutes, a 3 minute hold until 15 minutes, and then a drop back to 0% B at 15.1 minutes and allowed to equilibrate there until 25 minutes. |
Solvent A: | 100% water; 10 mM ammonium acetate; 10 mM tributylamine |
Solvent B: | 100% methanol |
Chromatography Type: | Ion pair |
Chromatography ID: | CH002872 |
Chromatography Summary: | PFPP A gradient separation on a Restek Ultra PFPP column (150 x 2.1 mm, 3 μm; Restek, Bellefonte, PA) was used to separate the analytes. Mobile phase A consisted of 0.1% formic acid in water and mobile phase B consisted of 0.1% formic acid in 100% acetonitrile. The gradient began with 2 minutes at 0% B followed by a ramp to 25% B between 2 and 5 minutes, another ramp to 35% B between 5 and 11 minutes, a final increase from 35% to 95% B between 11 and 15 minutes, a hold at 95% B from 15 to 20 minutes, then a decrease to 0% B between 20 and 20.10 minutes, and a final hold at 0% B from 20.10 to 25 minutes. The flow rate to achieve separation was 0.25 ml/min. Ionization in the negative ESI mode occurred in the DUIS source with the following conditions: nebulizing gas flow of 2 L/min, heating gas flow of 5 L/min, interface temperature of 350°C, DL temperature of 250°C, heat block temperature of 400°C, and a drying gas flow of 15 L/min. |
Instrument Name: | Shimadzu Nexera X2 |
Column Name: | Restek Ultra PFPP (150 x 2.1mm,3um) |
Flow Gradient: | The gradient began with 2 minutes at 0% B followed by a ramp to 25% B between 2 and 5 minutes, another ramp to 35% B between 5 and 11 minutes, a final increase from 35% to 95% B between 11 and 15 minutes, a hold at 95% B from 15 to 20 minutes, then a decrease to 0% B between 20 and 20.10 minutes, and a final hold at 0% B from 20.10 to 25 minutes. |
Flow Rate: | 0.25 ml/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile |
Chromatography Type: | Unspecified |