Return to study ST003104 main page

MB Sample ID: SA333608

Local Sample ID:young_7
Subject ID:SU003219
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:Young donors (aged 25 years or younger) and older donors (aged 50 years or older).
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005082 AN005083
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Agilent 1260 Agilent 1260
Column Waters Atlantis T3 (150 x 4.6mm,5um) Waters XBridge BEH Amide (100 x 2.1mm,2.5um)
MS Type API API
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap
Ion Mode POSITIVE NEGATIVE
Units abundance abundance

Chromatography:

Chromatography ID:CH003839
Chromatography Summary:Chromatographic method to detect analytes such as amino acids, endocannabinoids, fatty acid β-oxidation intermediates, gut-derived metabolites, nucleotides, neurotransmitters, cofactors and vitamins.
Instrument Name:Agilent 1260
Column Name:Waters Atlantis T3 (150 x 4.6mm,5um)
Column Temperature:40
Flow Gradient:The LC gradient program begins with an initial condition of 5% solvent A and 95% solvent B, with a flow rate of 0.25 mL/min, which is held for 0.5 minutes to establish system equilibration. The gradient then proceeds as follows: at 6 minutes, the mobile phase composition shifts to 60% solvent A and 40% solvent B for 3minutes; at 10 minutes, it changes back to 5% solvent A and 95% solvent B; at 11 minutes, the flow rate increases to 0.4 mL/min while maintaining a composition of 5% solvent A and 95% solvent B for a duration of 12.5 minutes; and at 24.5 minutes, the flow rate decreases back to 0.25 mL/min. The final condition is maintained for 1 minutes to ensure stability before subsequent analyses.
Flow Rate:0.250 – 0.400 mL/min
Solvent A:100% water; 0.1% formic acid; 10 mM ammonium formate (pH ~2.5)
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:HILIC
  
Chromatography ID:CH003840
Chromatography Summary:Chromatographic method to detect analytes including amino acids, nucleotides, nucleosides, nucleotide triphosphates, high energy intermediates, organic acids, TCA cycle intermediates, bile acids and vitamins.
Instrument Name:Agilent 1260
Column Name:Waters XBridge BEH Amide (100 x 2.1mm,2.5um)
Column Temperature:40
Flow Gradient:The LC gradient program is initialized with an initial mobile phase composition of 15% solvent A and 85% solvent B at a flow rate of 0.25 mL/min. Over the course of 8 minutes, the mobile phase composition undergoes a transition to 65% solvent A and 35% solvent B. Subsequently, at 8 minutes, the composition shifts to 98% solvent A and 2% solvent B, maintained for 1 minute. The mobile phase reverts back to the initial composition of 15% solvent A and 85% solvent B at 10 minutes. At 12.5 minutes, the flow rate is increased to 0.5 mL/min, while maintaining a constant mobile phase composition of 15% solvent A and 85% solvent B for a period of 2.5 minutes. Finally, at 15 minutes, the flow rate is reduced back to 0.25 mL/min. To ensure system stability, the final condition is maintained for 1 minute prior to subsequent analyses.
Flow Rate:0.250 – 0.400 mL/min
Solvent A:95% acetonitrile/5%; water 20mM ammonium acetate; 20mM ammonium hydroxide (pH 9.0)
Solvent B:100% acetonitrile
Chromatography Type:HILIC