Summary of Study ST002707

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001678. The data can be accessed directly via it's Project DOI: 10.21228/M8T146 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002707
Study TitleLevels of T3 (triiodothyronine) and T4 (thyroxine) in CSF (cerebrospinal fluid) and plasma as part of natural diurnal variation
Study SummaryThis study employs targeted LC-MS analysis of CSF and plasma to assess relative changes in the levels of thyroid hormone (T3: triiodothyronine and T4: thyroxine) at two time points in the diurnal cycle. For this purpose, wild-type CD1 mice were kept in a circadian cabinet housing with 12-hour light cycle (7 a.m. on/ 7 p.m. off) and tissues were collected consistently at an a.m and a p.m time point (9 a.m. and 9 p.m). CSF was collected from adult (3 months old). Internal standards (13C-labelled T3 and T4) as well as calibration curves were used to estimate the respective T3 and T4 concentration in the examined biofluids.
Institute
Boston Children's Hospital, Harvard Medical School
LaboratoryKanarek Lab
Last NamePetrova
First NameBoryana
AddressEnders 1116.2 300 Longwood Ave
EmailBoryana.Petrova@childrens.harvard.edu
Phone6179197352
Submit Date2023-05-15
Num Groups2
Total Subjects27
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-05-28
Release Version1
Boryana Petrova Boryana Petrova
https://dx.doi.org/10.21228/M8T146
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004389
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Ascentis Express C18 (150 x 2.1mm,2.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE
Units nM

Chromatography:

Chromatography ID:CH003292
Chromatography Summary:Ascentis Express C18 HPLC column (2.7 μm × 15 cm × 2.1 mm; Sigma Aldrich).
Instrument Name:Thermo Vanquish
Column Name:Ascentis Express C18 (150 x 2.1mm,2.7um)
Column Temperature:30
Flow Gradient:0–5 min: gradient was held at 5% B; 2–12.1 min: linear gradient of 5% to 95% B; 12.1–17.0 min: 95% B; 17.1–21.0 min: gradient was returned to 5% B
Flow Rate:0.250 ml/min
Solvent A:water, 0.1% formic acid
Solvent B:acetonitrile, 0.1% formic acid
Chromatography Type:Reversed phase
  logo