Summary of Study ST002722

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001688. The data can be accessed directly via it's Project DOI: 10.21228/M8HH7C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002722
Study TitleCirrhosis-related metabolomics study
Study SummaryThere are limited data on the diagnostic accuracy of gut microbial signatures for predicting hepatic decompensation in patients with cirrhosis. The aim of this study is to determine whether a stool genomic and metabolic signature accurately detects hepatic decompensation and mortality risk in cirrhosis secondary to nonalcoholic fatty liver disease (NAFLD). Shotgun metagenomic sequencing was performed on fecal samples collected from a prospective cohort of adults with NAFLD-related cirrhosis. The signatures were further validated with a metabolomic study on serum samples. Finally, we developed a Random Forest machine learning algorithm to make predictions on hepatic decompensation and mortality in NAFLD-related cirrhosis. Here we uploaded the metabolomics study data from LC-MS/MS.
Institute
University of British Columbia
Last NameZhao
First NameTingting
Address2036 Main Mall, V6T 1Z1
Emailtingzhao@chem.ubc.ca
Phone6048221253
Submit Date2023-05-30
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailLC-MS
Release Date2023-06-12
Release Version1
Tingting Zhao Tingting Zhao
https://dx.doi.org/10.21228/M8HH7C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004413
Analysis type MS
Chromatography type HILIC
Chromatography system 1290 Infinity II UHPLC system (Agilent Technologies)
Column Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
MS Type ESI
MS instrument type QTOF
MS instrument name Bruker Impact II QqTOF
Ion Mode POSITIVE
Units Height

Chromatography:

Chromatography ID:CH003312
Chromatography Summary:SeQuant ZIC-pHILIC Column (5 μm, 2.1 mm × 150 mm)
Instrument Name:1290 Infinity II UHPLC system (Agilent Technologies)
Column Name:Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
Column Temperature:30°C
Flow Gradient:0 min, 95% B; 20 min, 5% B; 25 min, 5% B; 25.01 min, 95% B; 30 min, 95% B; 35 min, 95% B.
Flow Rate:0.15 ml/min
Solvent A:10 mM ammonium acetate at pH 4.8
Solvent B:pure ACN
Chromatography Type:HILIC
  logo