Return to study ST001384 main page

MB Sample ID: SA101088

Local Sample ID:a351
Subject ID:SU001458
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002308 AN002309 AN002310 AN002311
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase Reversed phase
Chromatography system Shimadzu Prominence 20 UFLCXR Thermo Dionex Ultimate 3000 Shimadzu Prominence 20 UFLCXR Shimadzu Prominence 20 UFLCXR
Column Waters BEH C18 (100mm x 2.1mm; 1.7um) Waters XSelect HSS T3 (100 x 2.1mm,2.5um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type QTOF Orbitrap QTOF QTOF
MS instrument name ABI Sciex 5600 TripleTOF Thermo Exactive Plus Orbitrap ABI Sciex 5600 TripleTOF ABI Sciex 5600 TripleTOF
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Area Area Area

MS:

MS ID:MS002151
Analysis ID:AN002308
Instrument Name:ABI Sciex 5600 TripleTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The capillary voltage was set at 4.5 kV in negative ion mode, with a declustering potential of 80V. The mass spectrometer was operated in IDA (Information Dependent Acquisition) mode with a 100 ms survey scan from 100 to 1200 m/z, and up to 20 MS/MS product ion scans (100 ms) per duty cycle using a collision energy of 50V with a 20V spread. Data processing was performed using MS-DIAL and annotated using the built-in public library. Blank subtraction and analysis was performed in excel.
Ion Mode:POSITIVE
  
MS ID:MS002152
Analysis ID:AN002309
Instrument Name:Thermo Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Aquired in MS1 mode only. Data processing and annotation performed using MAVEN and an in-house targeted list. Blank subtraction and analysis was performed in excel.
Ion Mode:NEGATIVE
  
MS ID:MS002153
Analysis ID:AN002310
Instrument Name:ABI Sciex 5600 TripleTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:IDA MS2 method. Ammonium formate and formic acid were added to the positive ESI solvents. Data processing performed using MS-DIAL and annotated using the in silico library. Blank subtraction and analysis was performed in excel.
Ion Mode:POSITIVE
  
MS ID:MS002154
Analysis ID:AN002311
Instrument Name:ABI Sciex 5600 TripleTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:IDA MS2 method. Ammonium acetate was used for negative ESI solvents. Data processing performed using MS-DIAL and annotated using the in silico library. Blank subtraction and analysis was performed in excel.
Ion Mode:NEGATIVE