MB Sample ID: SA123883
Local Sample ID: | 48 |
Subject ID: | SU001524 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002421 | AN002422 | AN002423 | AN002424 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | HILIC | HILIC |
Chromatography system | Agilent 1260 Infinity | Agilent 1260 Infinity | Agilent 1290 Infinity | Agilent 1290 Infinity |
Column | Waters XBridge BEH Amide (15 cm x 2.1mm,2.5um) | Waters XBridge BEH Amide (15 cm x 2.1mm,2.5um) | Waters XBridge BEH Amide (15 cm x 2.1mm,2.5um) | Waters XBridge BEH Amide (15 cm x 2.1mm,2.5um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | QTOF | QTOF | QTOF | QTOF |
MS instrument name | Agilent 6520 QTOF | Agilent 6520 QTOF | Agilent 6545 QTOF | Agilent 6545 QTOF |
Ion Mode | POSITIVE | POSITIVE | POSITIVE | POSITIVE |
Units | Peak area | Peak area | Peak area | Peak area |
MS:
MS ID: | MS002258 |
Analysis ID: | AN002421 |
Instrument Name: | Agilent 6520 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The ESI conditions were as follows: Electrospray ion source ESI Agilent Jet Stream Technology in positive ionization mode; voltage 3.8 kV; desolvation temperature 325 °C; cone flow 20 L/h; desolvation gas flow 600 L/h; nebulizer pressure 45 psi, N2 drying gas; MS scan rate of 1.03 spectra/s across the range m/z 60-1000. The software, Progenesis Qi, was used to process raw data. In the results, every compound (feature) had at least two ions, like an ion and its isotope ion or adduct ion. Compounds with single ions were filtered out. If a compound had m/z information only, the m/z was directly used in the compound name. If a compound had neutral mass information, the neutral mass was converted to m/z. |
Ion Mode: | POSITIVE |
MS ID: | MS002259 |
Analysis ID: | AN002422 |
Instrument Name: | Agilent 6520 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The ESI conditions were as follows: Electrospray ion source ESI Agilent Jet Stream Technology in positive ionization mode; voltage 3.8 kV; desolvation temperature 325 °C; cone flow 20 L/h; desolvation gas flow 600 L/h; nebulizer pressure 45 psi, N2 drying gas; MS scan rate of 1.03 spectra/s across the range m/z 60-1000. The software, Progenesis Qi, was used to process raw data. In the results, every compound (feature) had at least two ions, like an ion and its isotope ion or adduct ion. Compounds with single ions were filtered out. If a compound had m/z information only, the m/z was directly used in the compound name. If a compound had neutral mass information, the neutral mass was converted to m/z. |
Ion Mode: | POSITIVE |
MS ID: | MS002260 |
Analysis ID: | AN002423 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | (Agilent 6545) MS scan rate of 1.03 spectra/s across the range m/z 60-1000. The software, Progenesis Qi, was used to process raw data. In the results, every compound (feature) had at least two ions, like an ion and its isotope ion or adduct ion. Compounds with single ions were filtered out. If a compound had m/z information only, the m/z was directly used in the compound name. If a compound had neutral mass information, the neutral mass was converted to m/z. |
Ion Mode: | POSITIVE |
MS ID: | MS002261 |
Analysis ID: | AN002424 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | (Agilent 6545) MS scan rate of 1.03 spectra/s across the range m/z 60-1000. The software, Progenesis Qi, was used to process raw data. In the results, every compound (feature) had at least two ions, like an ion and its isotope ion or adduct ion. Compounds with single ions were filtered out. If a compound had m/z information only, the m/z was directly used in the compound name. If a compound had neutral mass information, the neutral mass was converted to m/z. |
Ion Mode: | POSITIVE |