Return to study ST002016 main page
MB Sample ID: SA188865
Local Sample ID: | Pat_38_NEG |
Subject ID: | SU002097 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003284 | AN003285 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Thermo Accucore C18 (100 x 2.1mm,2.6um) | Thermo Accucore C18 (100 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Orbitrap ID-X Tribrid | Thermo Orbitrap ID-X Tribrid |
Ion Mode | POSITIVE | NEGATIVE |
Units | intensity | intensity |
MS:
MS ID: | MS003055 |
Analysis ID: | AN003284 |
Instrument Name: | Thermo Orbitrap ID-X Tribrid |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | HESI) source was operated at 3.5 kV and 2.5kV for positive and negative modes, respectively. Ion source sheath gas was set at 35 and auxiliary gas at 7. Ion transfer tube temperature was maintained at 275 °C while vaporizer temperature was maintained at 320 °C. The instrument was set to acquire over the m/z range 67-1000, in full MS mode (1 µscan) at a resolution of 60,000 at a normalized AGC Target of 25% and 50 milliseconds of maximum injection time was allowed. RF lens amplitude was set at 35%. Tandem MS/MS performed by applying quadrupole isolation with an isolation window of 1.6 m/z. Activation type was set at HCD and masses were fragmented with HCD Assisted Collision Energy (%) of 15,35,50. Fragment masses were detected by Orbitrap at a resolution of 15,000. |
Ion Mode: | POSITIVE |
MS ID: | MS003056 |
Analysis ID: | AN003285 |
Instrument Name: | Thermo Orbitrap ID-X Tribrid |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | HESI) source was operated at 3.5 kV and 2.5kV for positive and negative modes, respectively. Ion source sheath gas was set at 35 and auxiliary gas at 7. Ion transfer tube temperature was maintained at 275 °C while vaporizer temperature was maintained at 320 °C. The instrument was set to acquire over the m/z range 67-1000, in full MS mode (1 µscan) at a resolution of 60,000 at a normalized AGC Target of 25% and 50 milliseconds of maximum injection time was allowed. RF lens amplitude was set at 35%. Tandem MS/MS performed by applying quadrupole isolation with an isolation window of 1.6 m/z. Activation type was set at HCD and masses were fragmented with HCD Assisted Collision Energy (%) of 15,35,50. Fragment masses were detected by Orbitrap at a resolution of 15,000. |
Ion Mode: | NEGATIVE |