MB Sample ID: SA189938
Local Sample ID: | RS-01718580 |
Subject ID: | SU002107 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003295 |
---|---|
Analysis type | MS |
Chromatography type | GC |
Chromatography system | Leco Pegasus IV GC |
Column | Restek Rtx-5Sil (30m x 0.25mm,0.25um) |
MS Type | EI |
MS instrument type | GC-TOF |
MS instrument name | Leco Pegasus IV TOF |
Ion Mode | UNSPECIFIED |
Units | normalized peak height |
MS:
MS ID: | MS003065 |
Analysis ID: | AN003295 |
Instrument Name: | Leco Pegasus IV TOF |
Instrument Type: | GC-TOF |
MS Type: | EI |
MS Comments: | Gas Chromatography conditions: A 30 m long, 0.25 mm i.d. Rtx-5Sil MS column (0.25 μm 95% dimethyl 5% diphenyl polysiloxane film) with additional 10 m integrated guard column is used (Restek, Bellefonte PA). 99.9999% pure Helium with built-in purifier (Airgas, Radnor PA) is set at constant flow of 1 ml/min. The oven temperature is held constant at 50°C for 1 min and then ramped at 20°C/min to 330°C at which it is held constant for 5 min. Mass spectrometer settings: A Leco Pegasus IV time of flight mass spectrometer is controlled by the Leco ChromaTOF software vs. 2.32 (St. Joseph, MI). The transfer line temperature between gas chromatograph and mass spectrometer is set to 280°C. Electron impact ionization at 70V is employed with an ion source temperature of 250°C. Acquisition rate is 17 spectra/second, with a scan mass range of 85-500 Da. |
Ion Mode: | UNSPECIFIED |