Return to study ST002082 main page

MB Sample ID: SA198255

Local Sample ID:R-13_2018-04-23
Subject ID:SU002166
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:47-89 years
Gender:Male and female
Human Inclusion Criteria:Patients with lung cancer

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003396 AN003397 AN003398 AN003399
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Agilent 6550 Agilent 6550 Agilent 6550 Agilent 6550
Column Waters Atlantis dC18 (100 x 3mm,3um) Waters Atlantis dC18 (100 x 3mm,3um) Waters BEH Amide (150 x 3.0mm,1.7um) Waters BEH Amide (150 x 3.0mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type QTOF QTOF QTOF QTOF
MS instrument name Agilent 6550 QTOF Agilent 6550 QTOF Agilent 6550 QTOF Agilent 6550 QTOF
Ion Mode NEGATIVE POSITIVE NEGATIVE POSITIVE
Units Values are raw peak area raw peak area raw peak area Values are raw peak area

MS:

MS ID:MS003163
Analysis ID:AN003396
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Mass spectrometry conditions: The mass spectrometer was tuned and calibrated according to protocols recommended by the manufacturer. Acquisition was performed in 2 GHz mode and mass range 50-1700. The capillary voltage was 4000 V and fragmentor voltage 380 V. The desolvation gas temperature was 200 °C with flow rate at 15 L/min. The sheath gas temperature was 300 °C with flow rate at 12 L/min. The nebulizer pressure was 40 psig and nozzle voltage 1000 V (± for positive and negative ionisation modes). The acquisition rate was 3 spectra/second. The reference mass solution was continually infused at a flow rate of 0.5 mL/min by a separate isocratic pump for constant mass correction. Repeat injections of each pooled sample were interspersed throughout the analytical sequence, as per the quality control procedure described by Norman et al. (Clin Chem. 2019;65(4):530-539. doi: 10.1373/clinchem.2018.295345). The individual sample analysis order was randomised computationally. Data Pre-processing and Quality Control: All data were acquired using the MassHunter suite (Agilent build 6.0) with quality checks being performed by Qualitative Analysis (build 07.00). Mass accuracy was checked using extracted ion chromatograms of reference masses: the resulting accuracy was ±5 ppm during the run. Additionally, chromatographic reproducibility was checked by overlaying binary pump pressure curves across each analytical sequence. Data was filtered based upon the pooled QC samples, with compounds being retained if observed in 100 % of replicate injections for at least 1 pool and with peak area coefficient of variation (CV) <25 % across all replicate injections for each pool. A comprehensive semi-targeted approach was employed to assign the identity of urinary metabolites using an in-house compound library that included a broad range of metabolites involved in intermediary metabolism. Targeted feature extraction was performed on each dataset based on matching of metabolite chemical features against an accurate mass and retention time (AMRT) database previously generated from analysis of the IROA Technology MS metabolite library of tandards by each LC method described above, combined with the same QTOF analytical parameters used in this study (databases publicly available: https://doi.org/10.6084/m9.figshare.c.4378235.v2). In addition to accurate mass and retention time, MS/MS (data-dependent, employed for 'hit' metabolites) was also used in the confirmation of metabolite identity (i.e. level 1 identification) as per Sumner et al. Feature extraction was performed in MassHunter Profinder (build 10.0); accurate mass window of 10 ppm and retention time window of 0.3 min against the respective AMRT database. Data were exported in the format of a csv file for statistical analysis. Unidentified compounds are 'known unknowns' of interest from previous experiments; detection by matched AMRT and named in the format 'RT_neutral-mass'. 'BDRM'; unidentified bone-derived metabolite.
Ion Mode:NEGATIVE
  
MS ID:MS003164
Analysis ID:AN003397
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Mass spectrometry conditions: The mass spectrometer was tuned and calibrated according to protocols recommended by the manufacturer. Acquisition was performed in 2 GHz mode and mass range 50-1700. The capillary voltage was 4000 V and fragmentor voltage 380 V. The desolvation gas temperature was 200 °C with flow rate at 15 L/min. The sheath gas temperature was 300 °C with flow rate at 12 L/min. The nebulizer pressure was 40 psig and nozzle voltage 1000 V (± for positive and negative ionisation modes). The acquisition rate was 3 spectra/second. The reference mass solution was continually infused at a flow rate of 0.5 mL/min by a separate isocratic pump for constant mass correction. Repeat injections of each pooled sample were interspersed throughout the analytical sequence, as per the quality control procedure described by Norman et al. (Clin Chem. 2019;65(4):530-539. doi: 10.1373/clinchem.2018.295345). The individual sample analysis order was randomised computationally. Data Pre-processing and Quality Control: All data were acquired using the MassHunter suite (Agilent build 6.0) with quality checks being performed by Qualitative Analysis (build 07.00). Mass accuracy was checked using extracted ion chromatograms of reference masses: the resulting accuracy was ±5 ppm during the run. Additionally, chromatographic reproducibility was checked by overlaying binary pump pressure curves across each analytical sequence. Data was filtered based upon the pooled QC samples, with compounds being retained if observed in 100 % of replicate injections for at least 1 pool and with peak area coefficient of variation (CV) <25 % across all replicate injections for each pool. A comprehensive semi-targeted approach was employed to assign the identity of urinary metabolites using an in-house compound library that included a broad range of metabolites involved in intermediary metabolism. Targeted feature extraction was performed on each dataset based on matching of metabolite chemical features against an accurate mass and retention time (AMRT) database previously generated from analysis of the IROA Technology MS metabolite library of tandards by each LC method described above, combined with the same QTOF analytical parameters used in this study (databases publicly available: https://doi.org/10.6084/m9.figshare.c.4378235.v2). In addition to accurate mass and retention time, MS/MS (data-dependent, employed for 'hit' metabolites) was also used in the confirmation of metabolite identity (i.e. level 1 identification) as per Sumner et al. Feature extraction was performed in MassHunter Profinder (build 10.0); accurate mass window of 10 ppm and retention time window of 0.3 min against the respective AMRT database. Data were exported in the format of a csv file for statistical analysis. Unidentified compounds are 'known unknowns' of interest from previous experiments; detection by matched AMRT and named in the format 'RT_neutral-mass'. 'BDRM'; unidentified bone-derived metabolite.
Ion Mode:POSITIVE
  
MS ID:MS003165
Analysis ID:AN003398
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Mass spectrometry conditions: The mass spectrometer was tuned and calibrated according to protocols recommended by the manufacturer. Acquisition was performed in 2 GHz mode and mass range 50-1700. The capillary voltage was 4000 V and fragmentor voltage 380 V. The desolvation gas temperature was 200 °C with flow rate at 15 L/min. The sheath gas temperature was 300 °C with flow rate at 12 L/min. The nebulizer pressure was 40 psig and nozzle voltage 1000 V (± for positive and negative ionisation modes). The acquisition rate was 3 spectra/second. The reference mass solution was continually infused at a flow rate of 0.5 mL/min by a separate isocratic pump for constant mass correction. Repeat injections of each pooled sample were interspersed throughout the analytical sequence, as per the quality control procedure described by Norman et al. (Clin Chem. 2019;65(4):530-539. doi: 10.1373/clinchem.2018.295345). The individual sample analysis order was randomised computationally. Data Pre-processing and Quality Control: All data were acquired using the MassHunter suite (Agilent build 6.0) with quality checks being performed by Qualitative Analysis (build 07.00). Mass accuracy was checked using extracted ion chromatograms of reference masses: the resulting accuracy was ±5 ppm during the run. Additionally, chromatographic reproducibility was checked by overlaying binary pump pressure curves across each analytical sequence. Data was filtered based upon the pooled QC samples, with compounds being retained if observed in 100 % of replicate injections for at least 1 pool and with peak area coefficient of variation (CV) <25 % across all replicate injections for each pool. A comprehensive semi-targeted approach was employed to assign the identity of urinary metabolites using an in-house compound library that included a broad range of metabolites involved in intermediary metabolism. Targeted feature extraction was performed on each dataset based on matching of metabolite chemical features against an accurate mass and retention time (AMRT) database previously generated from analysis of the IROA Technology MS metabolite library of tandards by each LC method described above, combined with the same QTOF analytical parameters used in this study (databases publicly available: https://doi.org/10.6084/m9.figshare.c.4378235.v2). In addition to accurate mass and retention time, MS/MS (data-dependent, employed for 'hit' metabolites) was also used in the confirmation of metabolite identity (i.e. level 1 identification) as per Sumner et al. Feature extraction was performed in MassHunter Profinder (build 10.0); accurate mass window of 10 ppm and retention time window of 0.3 min against the respective AMRT database. Data were exported in the format of a csv file for statistical analysis.
Ion Mode:NEGATIVE
  
MS ID:MS003166
Analysis ID:AN003399
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Mass spectrometry conditions: The mass spectrometer was tuned and calibrated according to protocols recommended by the manufacturer. Acquisition was performed in 2 GHz mode and mass range 50-1700. The capillary voltage was 4000 V and fragmentor voltage 380 V. The desolvation gas temperature was 200 °C with flow rate at 15 L/min. The sheath gas temperature was 300 °C with flow rate at 12 L/min. The nebulizer pressure was 40 psig and nozzle voltage 1000 V (± for positive and negative ionisation modes). The acquisition rate was 3 spectra/second. The reference mass solution was continually infused at a flow rate of 0.5 mL/min by a separate isocratic pump for constant mass correction. Repeat injections of each pooled sample were interspersed throughout the analytical sequence, as per the quality control procedure described by Norman et al. (Clin Chem. 2019;65(4):530-539. doi: 10.1373/clinchem.2018.295345). The individual sample analysis order was randomised computationally. Data Pre-processing and Quality Control: All data were acquired using the MassHunter suite (Agilent build 6.0) with quality checks being performed by Qualitative Analysis (build 07.00). Mass accuracy was checked using extracted ion chromatograms of reference masses: the resulting accuracy was ±5 ppm during the run. Additionally, chromatographic reproducibility was checked by overlaying binary pump pressure curves across each analytical sequence. Data was filtered based upon the pooled QC samples, with compounds being retained if observed in 100 % of replicate injections for at least 1 pool and with peak area coefficient of variation (CV) <25 % across all replicate injections for each pool. A comprehensive semi-targeted approach was employed to assign the identity of urinary metabolites using an in-house compound library that included a broad range of metabolites involved in intermediary metabolism. Targeted feature extraction was performed on each dataset based on matching of metabolite chemical features against an accurate mass and retention time (AMRT) database previously generated from analysis of the IROA Technology MS metabolite library of tandards by each LC method described above, combined with the same QTOF analytical parameters used in this study (databases publicly available: https://doi.org/10.6084/m9.figshare.c.4378235.v2). In addition to accurate mass and retention time, MS/MS (data-dependent, employed for 'hit' metabolites) was also used in the confirmation of metabolite identity (i.e. level 1 identification) as per Sumner et al. Feature extraction was performed in MassHunter Profinder (build 10.0); accurate mass window of 10 ppm and retention time window of 0.3 min against the respective AMRT database. Data were exported in the format of a csv file for statistical analysis.
Ion Mode:POSITIVE