MB Sample ID: SA203982
Local Sample ID: | CID3 |
Subject ID: | SU002204 |
Subject Type: | Fish |
Subject Species: | Danio rerio |
Taxonomy ID: | 7955 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003467 | AN003468 | AN003469 | AN003470 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Waters Xbridge amide (100 x 2.1mm,3.5um) | Waters Xbridge amide (100 x 2.1mm,3.5um) | Waters Xbridge amide (100 x 2.1mm,3.5um) | Waters Xbridge amide (100 x 2.1mm,3.5um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | ion counts | ion counts | ion counts | ion counts |
MS:
MS ID: | MS003228 |
Analysis ID: | AN003467 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | It was operated in the full-scan mode (positive/negative switching) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch. |
Ion Mode: | POSITIVE |
MS ID: | MS003229 |
Analysis ID: | AN003468 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | It was operated in the full-scan mode (positive/negative switching) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch. |
Ion Mode: | NEGATIVE |
MS ID: | MS003230 |
Analysis ID: | AN003469 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | It was operated in the full-scan mode (positive ion mode only) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch. |
Ion Mode: | POSITIVE |
MS ID: | MS003231 |
Analysis ID: | AN003470 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | It was operated in the full-scan mode (negative ion mode only) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch. |
Ion Mode: | NEGATIVE |