MB Sample ID: SA207440

Local Sample ID:HFD-HV_45_12122
Subject ID:SU002247
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003540 AN003541
Analysis type MS MS
Chromatography type HILIC IR-MALDI
Chromatography system Thermo Vanquish Other
Column Waters XBridge BEH Amide (150mm x 2.1mm,2.5um) Other
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Exploris 240 Orbitrap
Ion Mode NEGATIVE NEGATIVE
Units Total Abundance Peak Area

MS:

MS ID:MS003298
Analysis ID:AN003540
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Fullscan mass spectrometry. The full scan mass spectrometry analysis was performed on a Thermo Q Exactive PLUS with a HESI source which was set to a spray voltage of -2.7kV under negative mode and 3.5kV under positive mode. The sheath, auxiliary, and sweep gas flow rates of 40, 10, and 2 (arbitrary unit), respectively. The capillary temperature was set to 300°C, and the aux gas heater was 360°C. The S-lens RF level was 45. The m/z range was set to 72 to 1000 m/z under both positive and negative ionization mode. The AGC target was set to 3e6, and the maximum IT was 200 ms. The mass resolution (full-width half maximum) was set to 70,000 @ m/z = 200.
Ion Mode:NEGATIVE
Analysis Protocol File:cwwong_methods.pdf
  
MS ID:MS003299
Analysis ID:AN003541
Instrument Name:Thermo Exploris 240 Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:To ablate targeted tissue regions a 2970-nm wavelength laser was used with a single burst of ten pulses to produce 1 mJ of energy at a rate of 10 kHz. X and Y stage movements of 100 µm were used to achieve oversampling(Nazari and Muddiman, 2015). Ablated analytes were post-ionized in the orthogonal electrospray plume, established by applying a voltage of approximately 3 kV to the electrospray solvent (1 mM acetic acid in 50:50 water/acetonitrile.) Mass spectrometry analysis of ionized molecules was performed in negative mode with internal calibrant used to achieve high mass accuracy (<2.5 ppm) within the 85-225 m/z range. Automatic gain control (AGC) was disabled. A mass resolution power of 240,000FWHM at 200 m/z was used with a fixed injection time (15 ms) to synchronize timing of the ablation plume with ion collection in the C-trap of the mass spectrometer.
Ion Mode:NEGATIVE
Analysis Protocol File:cwwong_methods.pdf