Combined analysis:

Analysis ID AN003599
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Vanquish Horizon
Column SeQuant ZIC-pHILIC
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Exploris 240
Ion Mode UNSPECIFIED
Units peak area

MS:

MS ID:MS003354
Analysis ID:AN003599
Instrument Name:Thermo Exploris 240
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolites were measured with Vanquish Horizon UHPLC coupled to an Orbitrap Exploris 240 mass spectrometer (both Thermo Fisher Scientific) via a heated electrospray ionization source. The spray voltages were set to +3.5kV/-2.8 kV, RF lens value at 70, the heated capillary held at 320 °C, and the auxiliary gas heater held at 280 °C. The flow rate for sheath gas, aux gas and sweep gas were set to 40, 15 and 0, respectively. For MS1 scans, mass range was set to m/z=70-900, AGC target set to standard and maximum injection time (IT) set to auto. Data acquisition for experimental samples used full scan mode with polarity switching at an Orbitrap resolution of 120000. Data acquisition for untargeted metabolite identification was performed using the AcquireX Deep Scan workflow, an iterative data-dependent acquisition (DDA) strategy using multiple injections of the pooled sample. In brief, sample was first injected in full scan-only mode in single polarity to create an automated inclusion list. MS2 acquisition was then carried out in triplicate, where ions on the inclusion list were prioritized for fragmentation in each run, after which both the exclusion and inclusion lists were updated in a manner where fragmented ions from the inclusion list were moved to exclusion list for the next run. DDA full scan-ddMS2 method for AcquireX workflow used the following parameters: full scan resolution was set to 60000, fragmentation resolution to 30000, fragmentation intensity threshold to 5.0e3. Dynamic exclusion was enabled after 1 time and exclusion duration was 10s. Mass tolerance was set to 5ppm. Isolation window was set to 1.2 m/z. Normalized HCD collision energies were set to stepped mode with values at 30, 50, 150. Fragmentation scan range was set to auto, AGC target at standard and max IT at auto. Xcalibur AcquireX method modification was on. Mild trapping was enabled. Metabolite identification was performed in the Compound Discoverer software (v 3.2, Thermo Fisher Scientific). Metabolites were annotated at the MS2 level using both an in-house mzVault spectral database curated from 1051 authentic compound standards and the online spectral library mzCloud. The precursor mass tolerance was set to 5 ppm and fragment mass tolerance set to 10 ppm. Only metabolites with mzVault or mzCloud best match score above 50% and 75%, respectively, and RT tolerance within 0.5 min to that of a purified standard run with the same chromatographic method were exported to generate a list including compound names, molecular formula and RT. The curated list was then used for further processing in the Tracefinder software (v 5.0, Thermo Fisher Scientific), where extracted ion chromatographs for all compound were examined and manually integrated if necessary. False positive, noise or chromatographically unresolved compounds were removed. The peak area for each detected metabolite was then normalized against the total ion count (TIC) of that sample to correct any variations introduced from sample handling through instrument analysis. The normalized areas were used as variables for further statistical data analysis.
Ion Mode:UNSPECIFIED