Return to study ST002269 main page

MB Sample ID: SA217579

Local Sample ID:H_C_256
Subject ID:SU002355
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:8.7-18.6 (year)
Gender:Male and female
Human Ethnicity:Korean
Human Inclusion Criteria:We recruited children and adolescent participants who visited the pediatric departments of the Hallym University Sacred Heart Hospital and Seoul National University Children’s Hospital from January 2019 to May 2020, after obtaining informed consent from the children and their parents.
Human Exclusion Criteria:We excluded participants who were taking alcohol or medications known to affect the results of liver function tests. Participants with viral hepatitis, such as hepatitis A, B, or C, or with Epstein–Barr virus, Wilson’s disease, autoimmune hepatitis, or muscular disease were also excluded.

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003706 AN003707 AN003708 AN003709
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase None (Direct infusion) None (Direct infusion)
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Biocrates AbsoluteIDQ p400 HR Kit UHPLC (PN 9120052121032) Biocrates AbsoluteIDQ p400 HR Kit UHPLC (PN 9120052121032) NA NA
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE POSITIVE POSITIVE POSITIVE
Units μM μM μM μM

MS:

MS ID:MS003455
Analysis ID:AN003706
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS acquisition method, data processing method and software used for feature assignments are described in analysis protocol file attached. Please refer sections 10.3 (MS acquisition parameters) and 9 (data processing) of the method file attached. The final quantitative results were exported to micromolar values with pooled quality control sample normalization by median. Subsequently, values under the lower limit of detection were imputed by one-fifth of the minimum positive values of their corresponding variables. These data were used for further analysis.
Ion Mode:POSITIVE
Acquisition Parameters File:UM-p400-HR-Thermo-3.pdf
Processing Parameters File:UM-p400-HR-Thermo-3.pdf
Analysis Protocol File:UM-p400-HR-Thermo-3.pdf
  
MS ID:MS003456
Analysis ID:AN003707
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS acquisition method, data processing method and software used for feature assignments are described in analysis protocol file attached. Please refer sections 10.3 (MS acquisition parameters) and 9 (data processing) of the method file attached. The final quantitative results were exported to micromolar values with pooled quality control sample normalization by median. Subsequently, values under the lower limit of detection were imputed by one-fifth of the minimum positive values of their corresponding variables. These data were used for further analysis.
Ion Mode:POSITIVE
Acquisition Parameters File:UM-p400-HR-Thermo-3.pdf
Processing Parameters File:UM-p400-HR-Thermo-3.pdf
Analysis Protocol File:UM-p400-HR-Thermo-3.pdf
  
MS ID:MS003457
Analysis ID:AN003708
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS acquisition method, data processing method and software used for feature assignments are described in analysis protocol file attached. Please refer sections 10.3 (MS acquisition parameters) and 5.3 (data processing) of the method file attached. The final quantitative results were exported to micromolar values with pooled quality control sample normalization by median. Subsequently, values under the lower limit of detection were imputed by one-fifth of the minimum positive values of their corresponding variables. These data were used for further analysis.
Ion Mode:POSITIVE
Acquisition Parameters File:UM-p400-HR-Thermo-3.pdf
Processing Parameters File:UM-MetIDQ-Oxygen-9.pdf
Analysis Protocol File:UM-p400-HR-Thermo-3.pdf
  
MS ID:MS003458
Analysis ID:AN003709
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS acquisition method, data processing method and software used for feature assignments are described in analysis protocol file attached. Please refer sections 10.3 (MS acquisition parameters) and 5.3 (data processing) of the method file attached. The final quantitative results were exported to micromolar values with pooled quality control sample normalization by median. Subsequently, values under the lower limit of detection were imputed by one-fifth of the minimum positive values of their corresponding variables. These data were used for further analysis.
Ion Mode:POSITIVE
Acquisition Parameters File:UM-p400-HR-Thermo-3.pdf
Processing Parameters File:UM-MetIDQ-Oxygen-9.pdf
Analysis Protocol File:UM-p400-HR-Thermo-3.pdf