Return to study ST002320 main page

MB Sample ID: SA227356

Local Sample ID:HCO72
Subject ID:SU002406
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:5-77
Weight Or Weight Range:NA
Height Or Height Range:NA
Gender:Male and female
Human Lifestyle Factors:Urban industrial; Rural industrial; Rural traditional; Isolated traditional
Human Alcohol Drug Use:NA
Human Nutrition:NA
Human Inclusion Criteria:NA
Human Exclusion Criteria:NA

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003787
Analysis type MS
Chromatography type Reversed phase
Chromatography system ThermoFisher Scientific Vanquish Flex Binary LC System
Column Kinetex C18 core-shell (50 x 2.1mm,1.7um,100Å)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE
Units Peak area

MS:

MS ID:MS003530
Analysis ID:AN003787
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:LC was performed on a ThermoFisher Scientific Vanquish Flex Binary LC System with a Kinetex C18 core-shell column (50 x 2.1 mm, 1.7 μM particle size, 100 Å pore size). LC column was kept at 40 °C and the sample compartment was held at 10 °C. The LC System was coupled to a ThermoFisher Scientific Q Exactive Plus Hybrid Quadrupole-Orbitrap Mass Spectrometer for MS/MS analysis. For the LC mobile phase, Solvent A was LC-MS grade water (Fisher Scientific) with 0.1% formic acid and Solvent B was LC-MS grade acetonitrile (Fisher Scientific) with 0.1% formic acid. Elution gradient started at 5% Solvent B for one minute, increased to 100% Solvent B until minute nine, held at 100% Solvent B for two minutes, dropped to 5% Solvent B over 30 seconds, and 5% Solvent B for one minute as re-equilibration. Samples were injected in random order with an injection volume of 5 μl. After elution, electrospray ionization was conducted with spray voltage of 3.8 kV, auxiliary gas flow rate of 10, auxiliary gas temperature at 350 °C, sheath gas flow rate at 35, and sweep gas flow at 0. Capillary temperature was 320 °C and S-lens RF was 50 V. MS1 scan range was 100-1,500 m/z, MS1 resolution was set to 35,000 and MS1 AGC target to 1e6. MS1 data were obtained in positive mode and MS2 data were obtained using data-dependent acquisition. In each cycle, 5 MS/MS scans of the most abundant ion were recorded. Both MS1 and MS2 injection times were set at 100 ms. MS2 resolutions were set to 17,500, MS2 AGC target was set to 5e5, and the inclusion window to 2 m/z. MS/MS was conducted at an apex trigger of 2-8 seconds and an exclusion window of 10 seconds. MS/MS collision energy gradually increased from 20-40%.
Ion Mode:POSITIVE
Capillary Temperature:320°C
Ionization:ESI
Analysis Protocol File:C18_RP_Pos_QEPlus_20180403_12.5mint_ddMS2_MS.txt
  logo