MB Sample ID: SA243658
Local Sample ID: | mx626289_OzAW_MB01 |
Subject ID: | SU002527 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Genotype Strain: | BALB/c |
Age Or Age Range: | 8-10 wks. |
Gender: | Male and female |
Animal Animal Supplier: | Envigo |
Animal Light Cycle: | 12/12 light/dark |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003972 | AN003973 | AN003974 | AN003975 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC | HILIC |
Chromatography system | Thermo Vanquish | Thermo Vanquish | Agilent 6490 | Agilent 6490 |
Column | Waters Acquity CSH C18 (100 x 2.1mm, 1.7um) | Waters Acquity CSH C18 (100 x 2.1mm, 1.7um) | Agilent HP5-MS (30m x 0.25mm, 0.25 um) | Agilent HP5-MS (30m x 0.25mm, 0.25 um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Relative abundance | Relative abundance | Relative abundance | Relative abundance |
MS:
MS ID: | MS003706 |
Analysis ID: | AN003972 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The ion source conditions were set as follows: spray voltage, -3.0 kV; sheath gas flow rate, 60 arbitrary units; aux gas flow rate, 25 arbitrary units; sweep gas flow rate, 2 arbitrary units; capillary temp, 300 °C; S-lens RF level, 50; Aux gas heater temp, 370 °C. The following acquisition parameters were used for MS1 analysis: resolution, 60000, AGC target, 1e6; Maximum IT, 100 ms; scan range 60-900 m/z; spectrum data type, centroid. Data dependent MS/MS parameters: resolution, 15000; AGC target, 1e5; maximum IT, 50 ms; loop count, 4; TopN, 4; isolation window, 1.0 m/z; fixed first mass, 70.0 m/z; (N)CE/ stepped nce, 20, 30, 40; spectrum data type, centroid; minimum AGC target, 8e3; intensity threshold, 1.6e5; exclude isotopes, on; dynamic exclusion, 3.0 s. To increase the total number of MS/MS spectra, five runs with iterative MS/MS exclusions were performed using the R package “IE-Omics”18 for both positive and negative electrospray conditions. |
Ion Mode: | POSITIVE |
MS ID: | MS003707 |
Analysis ID: | AN003973 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The ion source conditions were set as follows: spray voltage, -3.0 kV; sheath gas flow rate, 60 arbitrary units; aux gas flow rate, 25 arbitrary units; sweep gas flow rate, 2 arbitrary units; capillary temp, 300 °C; S-lens RF level, 50; Aux gas heater temp, 370 °C. The following acquisition parameters were used for MS1 analysis: resolution, 60000, AGC target, 1e6; Maximum IT, 100 ms; scan range 60-900 m/z; spectrum data type, centroid. Data dependent MS/MS parameters: resolution, 15000; AGC target, 1e5; maximum IT, 50 ms; loop count, 4; TopN, 4; isolation window, 1.0 m/z; fixed first mass, 70.0 m/z; (N)CE/ stepped nce, 20, 30, 40; spectrum data type, centroid; minimum AGC target, 8e3; intensity threshold, 1.6e5; exclude isotopes, on; dynamic exclusion, 3.0 s. To increase the total number of MS/MS spectra, five runs with iterative MS/MS exclusions were performed using the R package “IE-Omics”18 for both positive and negative electrospray conditions. |
Ion Mode: | NEGATIVE |
MS ID: | MS003708 |
Analysis ID: | AN003974 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The ion source conditions were set as follows: spray voltage, -3.0 kV; sheath gas flow rate, 60 arbitrary units; aux gas flow rate, 25 arbitrary units; sweep gas flow rate, 2 arbitrary units; capillary temp, 300 °C; S-lens RF level, 50; Aux gas heater temp, 370 °C. The following acquisition parameters were used for MS1 analysis: resolution, 60000, AGC target, 1e6; Maximum IT, 100 ms; scan range 60-900 m/z; spectrum data type, centroid. Data dependent MS/MS parameters: resolution, 15000; AGC target, 1e5; maximum IT, 50 ms; loop count, 4; TopN, 4; isolation window, 1.0 m/z; fixed first mass, 70.0 m/z; (N)CE/ stepped nce, 20, 30, 40; spectrum data type, centroid; minimum AGC target, 8e3; intensity threshold, 1.6e5; exclude isotopes, on; dynamic exclusion, 3.0 s. To increase the total number of MS/MS spectra, five runs with iterative MS/MS exclusions were performed using the R package “IE-Omics”18 for both positive and negative electrospray conditions. |
Ion Mode: | POSITIVE |
MS ID: | MS003709 |
Analysis ID: | AN003975 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The ion source conditions were set as follows: spray voltage, -3.0 kV; sheath gas flow rate, 60 arbitrary units; aux gas flow rate, 25 arbitrary units; sweep gas flow rate, 2 arbitrary units; capillary temp, 300 °C; S-lens RF level, 50; Aux gas heater temp, 370 °C. The following acquisition parameters were used for MS1 analysis: resolution, 60000, AGC target, 1e6; Maximum IT, 100 ms; scan range 60-900 m/z; spectrum data type, centroid. Data dependent MS/MS parameters: resolution, 15000; AGC target, 1e5; maximum IT, 50 ms; loop count, 4; TopN, 4; isolation window, 1.0 m/z; fixed first mass, 70.0 m/z; (N)CE/ stepped nce, 20, 30, 40; spectrum data type, centroid; minimum AGC target, 8e3; intensity threshold, 1.6e5; exclude isotopes, on; dynamic exclusion, 3.0 s. To increase the total number of MS/MS spectra, five runs with iterative MS/MS exclusions were performed using the R package “IE-Omics”18 for both positive and negative electrospray conditions. |
Ion Mode: | NEGATIVE |