Return to study ST002447 main page

MB Sample ID: SA244720

Local Sample ID:PA CP27_2_25_1_973
Subject ID:SU002536
Subject Type:Bacteria
Subject Species:Pseudomonas aeruginosa

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003988
Analysis type MS
Chromatography type Reversed phase
Chromatography system Bruker Elute
Column Hamilton Intensity Solo 2 C18 (100 x 2.1 mm, 1.8 µm, 90 Å)
MS Type ESI
MS instrument type QTOF
MS instrument name Bruker timsTOF
Ion Mode POSITIVE
Units AU

MS:

MS ID:MS003722
Analysis ID:AN003988
Instrument Name:Bruker timsTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Samples were chromatographically separated by inline reversed-phase chromatography using the Elute HPG 1300 pumps and Elute Autosampler (Bruker, Darmstadt, Germany) with solvent A 0.1% FA in HPLC grade water and solvent B 0.1% FA in ACN. A Hamilton Intensity Solo 2 C18 column (100 mm x 2.1 mm, 1.8 µm beads) was maintained at 35℃ (metabolomics analyses) For metabolomics, 10 µL was injected twice for each sample and eluted using a 30-minute gradient as follows: 1% ACN was held for 2 minutes, ramping to 99% ACN over 15 minutes, held at 99% ACN for 3 minutes before re-equilibrating to 1% ACN for 10 minutes. Flow rates were 250 µL/min for elution and 350 µL/min for re-equilibration. The MS analysis was performed using a TimsTOF (Bruker, Darmstadt, Germany) with Apollo II electrospray ionization (ESI) source. The drying gas was set to flow at 10 L/min and the drying temperature to 220℃ and the nebulizer pressure to 2.2 bar. The capillary voltage was 4500 V and the end plate offset 500V. For proteomics, the scan range was 150 – 2200 m/z, and for metabolomics 20-1300 m/z. For metabolomics the collision energy was set to 20 eV, the cycle time to 0.5 seconds with a relative minimum intensity threshold of 400 counts per thousand and target intensity of 20,000. Sodium formate was injected as an external calibrant in the first 0.3 minutes of each LC-MS/MS run. MetaboScape® 4.0 software was used for metabolite processing and statistical analysis (Bruker Daltonics). The following parameters for molecular feature identification and ‘bucketing’ were set in the T-ReX 2D/3D workflow: For peak detection, a minimum intensity threshold of 1,000 counts is required, as well as a minimum peak duration of 7 spectra, with feature quantification determine using peak area. The file masses were recalibrated based on the external calibrant injected between 0-0.3 min. Only features found in at least three of the twelve samples (per treatment), with retention time between 0.3 and 25 minutes and m/z between 50 and 1,000 were considered and the MS/MS import method was set to be averaged.
Ion Mode:POSITIVE