MB Sample ID: SA253211

Local Sample ID:Pool_1
Subject ID:SU002616
Subject Type:Bacteria
Subject Species:Eggerthella lenta
Taxonomy ID:84112
Genotype Strain:DSM 2243, Valencia, AB8n2

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004143 AN004144
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units relative ion counts relative ion counts

MS:

MS ID:MS003890
Analysis ID:AN004143
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Full MS-ddMS2 data was collected, an inclusion list was used to prioritize MS2 selection of metabolites from our in-house ‘local’ library, when additional scan bandwidth was available MS2 was collected in a data-dependent manner. Mass range was 60-900 mz, resolution was 60k (MS1) and 15k (MS2), centroid data was collected, loop count was 4, isolation window was 1.5 Da. In SIRM samples, deuterated internal standards were replaced with CUDA and Val-Tyr-Val to enable untargeted enrichment analysis. LC-MS/MS analysis conditions for SIRM metabolomics were identical to those used for standard untargeted metabolomics. Intra- and extracellular untargeted data generated from SIRM experiments was analyzed separately using Compound Discoverer version 3.3 (Thermo Scientific, Bremen, Germany). Samples treated with labeled compounds were always paired with matched samples treated with unlabeled compounds in order to correct for naturally occurring isotope abundances. Unlabeled samples were used for compound detection and formula assignment via isotope pattern-based prediction, spectral library matches, or mass lists matches. The isotope patterns and formulas from the sample files then served as a reference for the detection of potential isotopologues per compound in the labeled sample type. A specification of the full Compound Discoverer workflow is available at https://github.com/turnbaughlab/2022_Noecker_ElentaMetabolism.
Ion Mode:POSITIVE
  
MS ID:MS003891
Analysis ID:AN004144
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Full MS-ddMS2 data was collected, an inclusion list was used to prioritize MS2 selection of metabolites from our in-house ‘local’ library, when additional scan bandwidth was available MS2 was collected in a data-dependent manner. Mass range was 60-900 mz, resolution was 60k (MS1) and 15k (MS2), centroid data was collected, loop count was 4, isolation window was 1.5 Da. In SIRM samples, deuterated internal standards were replaced with CUDA and Val-Tyr-Val to enable untargeted enrichment analysis. LC-MS/MS analysis conditions for SIRM metabolomics were identical to those used for standard untargeted metabolomics. Intra- and extracellular untargeted data generated from SIRM experiments was analyzed separately using Compound Discoverer version 3.3 (Thermo Scientific, Bremen, Germany). Samples treated with labeled compounds were always paired with matched samples treated with unlabeled compounds in order to correct for naturally occurring isotope abundances. Unlabeled samples were used for compound detection and formula assignment via isotope pattern-based prediction, spectral library matches, or mass lists matches. The isotope patterns and formulas from the sample files then served as a reference for the detection of potential isotopologues per compound in the labeled sample type. A specification of the full Compound Discoverer workflow is available at https://github.com/turnbaughlab/2022_Noecker_ElentaMetabolism.
Ion Mode:NEGATIVE