Return to study ST002555 main page

MB Sample ID: SA256890

Local Sample ID:OUHSCPD-47
Subject ID:SU002656
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Female
Cell Biosource Or Supplier:SNU3297 and SNU3298, and patient-derived ovarian cancer cells, A#5, A#8, A#39 were from Seoul National University, Seoul, South Korea. Patient-derived ovarian cancer cells, ASC110515, ASC102315, ASC061616, ASC060915, ASC062915B and ASC011215 were from Stephenson Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
Cell Passage Number:3 to 5
Cell Counts:20 million cells

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004207 AN004208 AN004209 AN004210
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2mm, 1.7um) Waters Acquity BEH C18 (100 x 2mm, 1.7um) Waters Acquity BEH C18 (100 x 2mm, 1.7um) Waters Acquity BEH Amide (150 x 2.1mm, 1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units Fold change over standard Fold change over standard Fold change over standard Fold change over standard

MS:

MS ID:MS003954
Analysis ID:AN004207
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A detailed description of data processing including chromatographic alignment, QC practices, and compound identification has been described previously (PMID: 19624122, 20955607, 30242936). Missing values, if any, were imputed with the minimum observed value for each compound and the resulting data was median scaled.
Ion Mode:POSITIVE
  
MS ID:MS003955
Analysis ID:AN004208
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A detailed description of data processing including chromatographic alignment, QC practices, and compound identification has been described previously (PMID: 19624122, 20955607, 30242936). Missing values, if any, were imputed with the minimum observed value for each compound and the resulting data was median scaled.
Ion Mode:POSITIVE
  
MS ID:MS003956
Analysis ID:AN004209
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A detailed description of data processing including chromatographic alignment, QC practices, and compound identification has been described previously (PMID: 19624122, 20955607, 30242936). Missing values, if any, were imputed with the minimum observed value for each compound and the resulting data was median scaled.
Ion Mode:NEGATIVE
  
MS ID:MS003957
Analysis ID:AN004210
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A detailed description of data processing including chromatographic alignment, QC practices, and compound identification has been described previously (PMID: 19624122, 20955607, 30242936). Missing values, if any, were imputed with the minimum observed value for each compound and the resulting data was median scaled.
Ion Mode:NEGATIVE