MB Sample ID: SA270103

Local Sample ID:ABC-19770
Subject ID:SU002805
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004376 AN004377
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Infinity Agilent 1290 Infinity
Column Waters ACQUITY UPLC BEH C18 (50 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (50 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6546 QTOF Agilent 6546 QTOF
Ion Mode POSITIVE NEGATIVE
Units normalized peak heights normalized peak heights

MS:

MS ID:MS004125
Analysis ID:AN004376
Instrument Name:Agilent 6546 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700. Agilent 6546 is equipped with a dual JetStream Source. modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 320°C, Gas Flow 8 l/min, Nebulizer 35 psi, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 175V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 5 scans per second. In negative ion mode, Gas Temp 360°C, Gas Flow 9 l/min, Fragmentor 120V, with the other parameters identical to positive ion mode. A reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction.
Ion Mode:POSITIVE
  
MS ID:MS004126
Analysis ID:AN004377
Instrument Name:Agilent 6546 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700. Agilent 6546 is equipped with a dual JetStream Source. modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 320°C, Gas Flow 8 l/min, Nebulizer 35 psi, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 175V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 5 scans per second. In negative ion mode, Gas Temp 360°C, Gas Flow 9 l/min, Fragmentor 120V, with the other parameters identical to positive ion mode. A reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction.
Ion Mode:NEGATIVE