Return to study ST002761 main page

MB Sample ID: SA290969

Local Sample ID:20211015_Cowley3_Urine_14_39-417-HS14-U_C18neg_rep
Subject ID:SU002868
Subject Type:Mammal
Subject Species:Rattus norvegicus
Taxonomy ID:10116

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004487 AN004488 AN004489 AN004490
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Agilent InfinityLab Poroshell 120 EC-C18 (2.1 x 50 mm; 2.7-Micron) Agilent InfinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) Agilent InfinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) Agilent InfiinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Area Area Area Area

MS:

MS ID:MS004234
Analysis ID:AN004487
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:C18 positive urine data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:POSITIVE
  
MS ID:MS004235
Analysis ID:AN004488
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:C18 negative urine data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:NEGATIVE
  
MS ID:MS004236
Analysis ID:AN004489
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:HILIC positive urine data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:POSITIVE
  
MS ID:MS004237
Analysis ID:AN004490
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:HILIC negative urine data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow.
Ion Mode:NEGATIVE
  logo