Return to study ST002789 main page

MB Sample ID: SA299219

Local Sample ID:180821_Smp_MS6C315m_C.mzML
Subject ID:SU002896
Subject Type:Other organism
Subject Species:Natural mixed marine microbial community

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004538 AN004539
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Waters Acquity I-Class Waters Acquity I-Class
Column SeQuant ZIC-HILIC (150 x 2.1mm, 5um) SeQuant ZIC-HILIC (150 x 2.1mm, 5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units normalized peak area per liter seawater filtered normalized peak area per liter seawater filtered

MS:

MS ID:MS004285
Analysis ID:AN004538
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolomic data was collected on a Thermo Q Exactive HF hybrid Orbitrap (QE) mass spectrometer. The capillary and auxiliary gas heater temperatures were maintained at 320°C and 100°C, respectively. The S-lens RF level was kept at 65, the H-ESI voltage was set to 3.3 kV and sheath gas, auxiliary gas, and sweep gas flow rates were set at 16, 3, and 1, respectively. Polarity switching was used with a scan range of 60 to 900 m/z and a resolution of 60,000. Calibration was performed every 3-4 days at a target mass of 200 m/z. All files were then converted to an open-source mzML format and centroided via Proteowizard’s msConvert tool. Skyline was used to for manual integration and QC of quantified data, while XCMS was used with a custom QC method for peak area data and each feature manually reviewed.
Ion Mode:POSITIVE
  
MS ID:MS004286
Analysis ID:AN004539
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolomic data was collected on a Thermo Q Exactive HF hybrid Orbitrap (QE) mass spectrometer. The capillary and auxiliary gas heater temperatures were maintained at 320°C and 100°C, respectively. The S-lens RF level was kept at 65, the H-ESI voltage was set to 3.3 kV and sheath gas, auxiliary gas, and sweep gas flow rates were set at 16, 3, and 1, respectively. Polarity switching was used with a scan range of 60 to 900 m/z and a resolution of 60,000. Calibration was performed every 3-4 days at a target mass of 200 m/z. All files were then converted to an open-source mzML format and centroided via Proteowizard’s msConvert tool. Skyline was used to for manual integration and QC of quantified data, while XCMS was used with a custom QC method for peak area data with the model trained on positive mode data applied to these negative mode results.
Ion Mode:NEGATIVE
  logo