Return to study ST002817 main page

MB Sample ID: SA302615

Local Sample ID:MtdBlank001
Subject ID:SU002926
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004584 AN004585 AN004586
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290 Waters Acquity
Column Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um) Waters ACQUITY UPLC CSH C18 (100 x 1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI ESI
MS instrument type QTOF QTOF Orbitrap
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE
Units peak heights peak heights raw area counts rescaled to set the median equal to 1

MS:

MS ID:MS004330
Analysis ID:AN004584
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:POSITIVE
  
MS ID:MS004331
Analysis ID:AN004585
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The quadrupole/time-of-flight (QTOF) mass spectrometers are operated with electrospray ionization (ESI) performing full scan in the mass range m/z 65–1700 in positive (Agilent 6530, equipped with a JetStreamSource) and negative (Agilent 6550, equipped with a dual JetStream Source) modes producing both unique and complementary spectra. Instrument parameters are as follows (positive mode) Gas Temp 325°C, Gas Flow 8 l/min, Nebulizer 35 psig, Sheath Gas 350°C, Sheath Gas Flow 11, Capillary Voltage 3500 V, Nozzle Voltage 1000V, Fragmentor 120V, Skimmer 65V. Data (both profile and centroid) are collected at a rate of 2 scans per second. In negative ion mode, Gas Temp 200°C, Gas Flow 14 l/min, Fragmentor 175V, with the other parameters identical to positive ion mode. For the 6530 QTOF, a reference solution generating ions of 121.050 and 922.007 m/z in positive mode and 119.036 and 966.0007 m/z in negative mode, and these are used for continuous mass correction. For the 6550, the reference solution is introduced via a dual spray ESI, with the same ions and continuous mass correction
Ion Mode:NEGATIVE
  
MS ID:MS004332
Analysis ID:AN004586
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos early)
Ion Mode:POSITIVE
  logo