Combined analysis:

Analysis ID AN004654 AN004655 AN004656 AN004657
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units peak area peak area peak area peak area

MS:

MS ID:MS004401
Analysis ID:AN004654
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos early). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill.
Ion Mode:POSITIVE
Analysis Protocol File:preprocessing_workflow.docx
  
MS ID:MS004402
Analysis ID:AN004655
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos late). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill.
Ion Mode:POSITIVE
Analysis Protocol File:preprocessing_workflow.docx
  
MS ID:MS004403
Analysis ID:AN004656
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Neg). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill.
Ion Mode:NEGATIVE
Analysis Protocol File:preprocessing_workflow.docx
  
MS ID:MS004404
Analysis ID:AN004657
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Polar). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill.
Ion Mode:NEGATIVE
Analysis Protocol File:preprocessing_workflow.docx