Return to study ST002911 main page

MB Sample ID: SA316319

Local Sample ID:1_UI4
Subject ID:SU003024
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Age Or Age Range:Seven- to eight-week-old female BALB/c mice
Gender:Female
Animal Animal Supplier:Jackson Laboratories

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004780 AN004781
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Infinity II Agilent 1290 Infinity II
Column Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6545 QTOF Agilent 6545 QTOF
Ion Mode POSITIVE NEGATIVE
Units AREA AREA

MS:

MS ID:MS004526
Analysis ID:AN004780
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:150 V fragmentor, 65 V skimmer, 3500 V capillary voltage, 750 V octopole radio frequency voltage, 10 L/min nebulizer gas flow, 200 °C gas temperature, 50 psi nebulizer gas pressure, 12 L/min sheath gas flow, and 300 °C sheath gas temperature. Data were collected in positive and negative ESI modes in separate runs, operated in full scan mode from 40 to 1700 m/z with a scan rate of 3 spectra/s. A solution consisting of two reference mass compounds was infused throughout the whole analysis: purine (C5H4N4) at m/z 121.0509 and HP-0921 (C18H18O6N3P3F24) at m/z 922.0098. These masses were continuously infused into the system through an Agilent 1260 Iso Pump at a 1 mL/min (split ratio 1:100) to provide a constant mass correction.
Ion Mode:POSITIVE
  
MS ID:MS004527
Analysis ID:AN004781
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:150 V fragmentor, 65 V skimmer, 3500 V capillary voltage, 750 V octopole radio frequency voltage, 10 L/min nebulizer gas flow, 200 °C gas temperature, 50 psi nebulizer gas pressure, 12 L/min sheath gas flow, and 300 °C sheath gas temperature. Data were collected in positive and negative ESI modes in separate runs, operated in full scan mode from 40 to 1700 m/z with a scan rate of 3 spectra/s. A solution consisting of two reference mass compounds was infused throughout the whole analysis: purine (C5H4N4) at m/z 119.0363 and HP-0921 (C18H18O6N3P3F24) at m/z 980.0163 (HP-0921 + acetate). These masses were continuously infused into the system through an Agilent 1260 Iso Pump at a 1 mL/min (split ratio 1:100) to provide a constant mass correction.
Ion Mode:NEGATIVE
  logo