MB Sample ID: SA322957

Local Sample ID:MB-A3
Subject ID:SU003079
Subject Type:Plant
Subject Species:Corydalis yanhusuo

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004873 AN004874
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system SHIMADZU Nexera X2 SHIMADZU Nexera X2
Column Agilent ZORBAX RRHD SB-C18 (100 x 2.1mm,1.8um) Agilent ZORBAX RRHD SB-C18 (100 x 2.1mm,1.8um)
MS Type ESI APCI
MS instrument type QTRAP QTRAP
MS instrument name ABI Sciex API 4000 QTrap ABI Sciex API 4000 QTrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

MS:

MS ID:MS004617
Analysis ID:AN004873
Instrument Name:ABI Sciex API 4000 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:LIT and triple quadrupole (QQQ) scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (Q TRAP), AB4500 Q TRAP UPLC/MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (AB Sciex). The ESI source operation parameters were as follows: ion source, turbo spray; source temperature 550°C; ion spray voltage (IS) 5500 V (positive ion mode)/-4500 V (negative ion mode); ion source gas I (GSI), gas II(GSII), curtain gas (CUR) were set at 50, 60, and 25.0 psi, respectively; the collision-activated dissociation(CAD) was high. Instrument tuning and mass calibration were performed with 10 and 100 μmol/L polypropylene glycol solutions in QQQ and LIT modes, respectively. QQQ scans were acquired as MRM experiments with collision gas (nitrogen) set to medium. DP and CE for individual MRM transitions was done with further DP and CE optimization. A specific set of MRM transitions were monitored for each period according to the metabolites eluted within this period.
Ion Mode:POSITIVE
  
MS ID:MS004618
Analysis ID:AN004874
Instrument Name:ABI Sciex API 4000 QTrap
Instrument Type:QTRAP
MS Type:APCI
MS Comments:LIT and triple quadrupole (QQQ) scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (Q TRAP), AB4500 Q TRAP UPLC/MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (AB Sciex). The ESI source operation parameters were as follows: ion source, turbo spray; source temperature 550°C; ion spray voltage (IS) 5500 V (positive ion mode)/-4500 V (negative ion mode); ion source gas I (GSI), gas II(GSII), curtain gas (CUR) were set at 50, 60, and 25.0 psi, respectively; the collision-activated dissociation(CAD) was high. Instrument tuning and mass calibration were performed with 10 and 100 μmol/L polypropylene glycol solutions in QQQ and LIT modes, respectively. QQQ scans were acquired as MRM experiments with collision gas (nitrogen) set to medium. DP and CE for individual MRM transitions was done with further DP and CE optimization. A specific set of MRM transitions were monitored for each period according to the metabolites eluted within this period.
Ion Mode:NEGATIVE