Return to study ST002993 main page

MB Sample ID: SA325868

Local Sample ID:C1520
Subject ID:SU003106
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004913 AN004914 AN004915 AN004916 AN004917
Analysis type MS MS MS MS MS
Chromatography type Reversed phase Reversed phase GC CE CE
Chromatography system Agilent 1290 Infinity II Agilent 1290 Infinity II Agilent 8890 GC System Agilent 7100 CE Agilent 7100 CE
Column Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) Agilent DB5-MS (30m x 0.25mm, 0.25um) Agilent Technologies fused silica capillary (total length, 100 cm; internal diameter, 50 µm) Agilent Technologies fused polyvinyl alcohol capillary PVA (total length, 97.6 cm; internal diameter, 50 µm)
MS Type ESI ESI EI ESI EI
MS instrument type QTOF QTOF Single quadrupole TOF TOF
MS instrument name Agilent 6545 QTOF Agilent 6545 QTOF Agilent 5977B Agilent 6230 TOF Agilent 6224 TOF
Ion Mode POSITIVE NEGATIVE POSITIVE POSITIVE NEGATIVE
Units Corrected areas Corrected areas Corrected areas Corrected areas Corrected areas

MS:

MS ID:MS004656
Analysis ID:AN004913
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The Agilent 6545 QTOF mass spectrometer equipped with a dual AJS ESI ion source was set with the following parameters: 150 V fragmentor, 65 V skimmer, 3500 V capillary voltage, 750 V octopole radio frequency voltage, 10 L/min nebulizer gas flow, 200 °C gas temperature, 50 psi nebulizer gas pressure, 12 L/min sheath gas flow, and 300 °C sheath gas temperature. Data were collected in positive ESI mode, operated in full scan mode from 40 to 1200 m/z with a scan rate of 3 spectra/s. We use two reference mass compounds throughout the whole analysis: purine (C5H4N4) at m/z 121.0509; and HP-0921 (C18H18O6N3P3F24) at m/z 922.0098. These masses were continuously infused into the system through an Agilent 1260 Iso Pump at a 1 mL/min (split ratio 1:100) to provide a constant mass correction. Data was acquired using Agilent MassHunter Workstation Software LC/MS Data Acquisition for 6200 series TOF/6500 series Q-TOF B 9.0.9044.0 (Agilent Technologies). The raw data were processed using Agilent Technologies MassHunter Profinder B.10.0.2.162 (Santa Clara, United States) to clean the background noise and unrelated ions.
Ion Mode:POSITIVE
  
MS ID:MS004657
Analysis ID:AN004914
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The Agilent 6545 QTOF mass spectrometer equipped with a dual AJS ESI ion source was set with the following parameters: 150 V fragmentor, 65 V skimmer, 3500 V capillary voltage, 750 V octopole radio frequency voltage, 10 L/min nebulizer gas flow, 200 °C gas temperature, 50 psi nebulizer gas pressure, 12 L/min sheath gas flow, and 300 °C sheath gas temperature. Data were collected in negative ESI mode, operated in full scan mode from 40 to 1200 m/z with a scan rate of 3 spectra/s. We use two reference mass compounds throughout the whole analysis: purine (C5H4N4) at m/z 119.0363 and HP-0921 (C18H18O6N3P3F24) at m/z 980.0163 (HP-0921 + acetate). These masses were continuously infused into the system through an Agilent 1260 Iso Pump at a 1 mL/min (split ratio 1:100) to provide a constant mass correction. Data was acquired using Agilent MassHunter Workstation Software LC/MS Data Acquisition for 6200 series TOF/6500 series Q-TOF B 9.0.9044.0 (Agilent Technologies).
Ion Mode:NEGATIVE
  
MS ID:MS004658
Analysis ID:AN004915
Instrument Name:Agilent 5977B
Instrument Type:Single quadrupole
MS Type:EI
MS Comments:The operating parameters of electronic impact ionization were established as follows: filament source temperature at 230 ° C and electronic ionization energy at 70 eV. Mass spectra were collected in a mass range of 50 to 600 m/z at a scan rate of 2 spectra per second. Data was acquired using Agilent MassHunter Workstation GC/MS Data Acquisition B 10.0.384.1 software (Agilent Technologies).
Ion Mode:POSITIVE
  
MS ID:MS004659
Analysis ID:AN004916
Instrument Name:Agilent 6230 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Mass spectrometry was operated in positive polarity, with a mass range 70–1000 m/z at a rate of 1.36 spectrum /s. Other parameters for the MS were: fragmentor at 125 V, skimmer at 65 V, OctopoleRFPeak at 750 V, drying gas temperature at 200 °C, flow at 10 L/min, nebulizer at 0 psig and capillary voltage at 3500 V. The sheath liquid used consisted of methanol: water (1:1, v/v) and two reference masses (20 μL of purine: 121.0509 and 20 μL of HP-0922: 922.0098) at a flow rate of 0.6 mL/min (1:100 of split ratio). The MS data in positive ionization were acquired using the Agilent MassHunter Workstation Software LC/MS Data Acquisition for 6200 series TOF/6500 series Q-TOF B 9.0.9044.0 (Agilent Technologies), and the raw data were inspected with the MassHunter Qualitative software (version B.08.00, Agilent Technologies) before data processing.
Ion Mode:POSITIVE
  
MS ID:MS004660
Analysis ID:AN004917
Instrument Name:Agilent 6224 TOF
Instrument Type:TOF
MS Type:EI
MS Comments:. Mass spectrometry was operated in negative polarity, with a mass range 60–1000 m/z at a rate of 1.0 spectrum /s. Other parameters for the MS were: fragmentor at 125 V, skimmer at 65 V, OctopoleRFPeak at 750 V, drying gas temperature at 275 °C, flow at 10 L/min, nebulizer at 0 psig and capillary voltage at 2000 V. The sheath liquid used consisted of methanol: water (1:1, v/v) and two reference masses (20 μL of purine: 121.0509 and 20 μL of HP-0922: 922.0098) at a flow rate of 0.6 mL/min (1:100 of split ratio). The MS data in negative ionization were acquired using the Agilent MassHunter Workstation Software LC/MS Data Acquisition for 6200 series TOF/6500 series Q-TOF B 6.01.6172 SP1 (Agilent Technologies), and the raw data were inspected with the MassHunter Qualitative software (version B.08.00, Agilent Technologies) before data processing.
Ion Mode:NEGATIVE
  logo