Return to study ST003127 main page
MB Sample ID: SA338938
Local Sample ID: | HL_HetHFD_3 |
Subject ID: | SU003244 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005126 | AN005127 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Imtakt Cadenza CD-C18 (150 x 2.1mm, 3um) | Imtakt Cadenza CD-C18 (150 x 2.1mm, 3um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak Intensity | Peak Intensity |
MS:
MS ID: | MS004862 |
Analysis ID: | AN005126 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | A data-dependent mass spectrometric acquisition method was used for lipid identification. In this method, each MS survey scan was followed by up to 10 MS/MS scans performed on the most abundant ions. Data was acquired in positive and negative mode in separate runs. The following electrospray parameters were used: spray voltage 3.0 kV, heated capillary temperature 350 °C, HESI probe temperature 350 °C, sheath gas, 35 units; auxiliary gas 10 units. For MS scans: resolution, 70,000 (at m/z 200); automatic gain control target, 3e6; maximum injection time, 200 ms; scan range, 250-1800 m/z. For MS/MS scans: resolution, 17,500 (at 200 m/z); automatic gain control target, 1e5 ions; maximum injection time, 75 ms; isolation window, 1 m/z; NCE, stepped 20,30 and 40. The LC-MS results were processed using MS-DIAL software (version 4.9) for lipid identification and relative quantitation. |
Ion Mode: | POSITIVE |
Analysis Protocol File: | Method_Lipidomics.pdf |
MS ID: | MS004863 |
Analysis ID: | AN005127 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | A data-dependent mass spectrometric acquisition method was used for lipid identification. In this method, each MS survey scan was followed by up to 10 MS/MS scans performed on the most abundant ions. Data was acquired in positive and negative mode in separate runs. The following electrospray parameters were used: spray voltage 3.0 kV, heated capillary temperature 350 °C, HESI probe temperature 350 °C, sheath gas, 35 units; auxiliary gas 10 units. For MS scans: resolution, 70,000 (at m/z 200); automatic gain control target, 3e6; maximum injection time, 200 ms; scan range, 250-1800 m/z. For MS/MS scans: resolution, 17,500 (at 200 m/z); automatic gain control target, 1e5 ions; maximum injection time, 75 ms; isolation window, 1 m/z; NCE, stepped 20,30 and 40. The LC-MS results were processed using MS-DIAL software (version 4.9) for lipid identification and relative quantitation. |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | Method_Lipidomics.pdf |