Return to study ST003127 main page

MB Sample ID: SA338961

Local Sample ID:HL_WTHFD_7
Subject ID:SU003244
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005126 AN005127
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Imtakt Cadenza CD-C18 (150 x 2.1mm, 3um) Imtakt Cadenza CD-C18 (150 x 2.1mm, 3um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak Intensity Peak Intensity

MS:

MS ID:MS004862
Analysis ID:AN005126
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A data-dependent mass spectrometric acquisition method was used for lipid identification. In this method, each MS survey scan was followed by up to 10 MS/MS scans performed on the most abundant ions. Data was acquired in positive and negative mode in separate runs. The following electrospray parameters were used: spray voltage 3.0 kV, heated capillary temperature 350 °C, HESI probe temperature 350 °C, sheath gas, 35 units; auxiliary gas 10 units. For MS scans: resolution, 70,000 (at m/z 200); automatic gain control target, 3e6; maximum injection time, 200 ms; scan range, 250-1800 m/z. For MS/MS scans: resolution, 17,500 (at 200 m/z); automatic gain control target, 1e5 ions; maximum injection time, 75 ms; isolation window, 1 m/z; NCE, stepped 20,30 and 40. The LC-MS results were processed using MS-DIAL software (version 4.9) for lipid identification and relative quantitation.
Ion Mode:POSITIVE
Analysis Protocol File:Method_Lipidomics.pdf
  
MS ID:MS004863
Analysis ID:AN005127
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A data-dependent mass spectrometric acquisition method was used for lipid identification. In this method, each MS survey scan was followed by up to 10 MS/MS scans performed on the most abundant ions. Data was acquired in positive and negative mode in separate runs. The following electrospray parameters were used: spray voltage 3.0 kV, heated capillary temperature 350 °C, HESI probe temperature 350 °C, sheath gas, 35 units; auxiliary gas 10 units. For MS scans: resolution, 70,000 (at m/z 200); automatic gain control target, 3e6; maximum injection time, 200 ms; scan range, 250-1800 m/z. For MS/MS scans: resolution, 17,500 (at 200 m/z); automatic gain control target, 1e5 ions; maximum injection time, 75 ms; isolation window, 1 m/z; NCE, stepped 20,30 and 40. The LC-MS results were processed using MS-DIAL software (version 4.9) for lipid identification and relative quantitation.
Ion Mode:NEGATIVE
Analysis Protocol File:Method_Lipidomics.pdf
  logo