Return to study ST003128 main page

MB Sample ID: SA339037

Local Sample ID:S_WTHFD_5
Subject ID:SU003245
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005128 AN005129 AN005130
Analysis type MS MS MS
Chromatography type HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column SeQuant ZIC-pHILIC (150 x 2.1mm, 5um) Imtakt Cadenza CD-C18 (150 x 2.1 mm, 3um) Imtakt Cadenza CD-C18 (150 x 2.1 mm, 3um)
MS Type ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode UNSPECIFIED NEGATIVE POSITIVE
Units Peak Intensity Peak Intensity Peak Intensity

MS:

MS ID:MS004864
Analysis ID:AN005128
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS data was processed using XCalibur 4.1 (Thermo Scientific) to obtain the metabolite signal intensity for relative quantitation. Targeted identification was available for 205 metabolites based on an in-house library established using known chemical standards. Identification required exact mass (within 5ppm) and standard retention times. For untargeted metabolomics, metabolites were identified by mass matching of the MS signal to metabolites in the HMDB database. If multiple metabolites in the database were matched to a certain MS signal, all matched metabolites were grouped into a single identification, and ordered based on the number of references included in the HMDB database (high to low).
Ion Mode:UNSPECIFIED
Analysis Protocol File:Serum_MS_and_Data_Analysis.pdf
  
MS ID:MS004865
Analysis ID:AN005129
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Identification of free fatty acids was based on accurate masses within 5 ppm and standard retention times from compound standards. Relative quantitation was performed based on MS signal intensities.
Ion Mode:NEGATIVE
Analysis Protocol File:Serum_MS_and_Data_Analysis.pdf
  
MS ID:MS004866
Analysis ID:AN005130
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A data-dependent mass spectrometric acquisition method was used for lipid identification. In this method, each MS survey scan was followed by up to 10 MS/MS scans performed on the most abundant ions. The LC-MS results were processed using MS-DIAL software (version 4.9) for lipid identification and relative quantitation.
Ion Mode:POSITIVE
Analysis Protocol File:Serum_MS_and_Data_Analysis.pdf