MoNA MS database records for (E)-3-(4-Hydroxyphenyl)-2-propenal
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PR309443 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M-H]- | negative | MS2 |
PR310503 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
RIKENPlaSMA008081 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008087 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008088 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008094 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008095 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008083 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008090 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008097 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008085 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008092 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA008099 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA004040 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004041 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004047 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004049 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004055 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004057 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004043 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004051 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004059 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004045 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004053 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA004061 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |