Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA016210 | Q-TOF SYNAPT, Waters | - | Electrospray Ionization (ESI) | 25 eV | [M+H]+ | positive | MS2 |
PM013507 | LCQ Deca | QIT | ESI | 35% | [M+H]+ | positive | MS2 |
PB001448 | TSQ 7000 | LC-ESI-QQ | ESI | 30 eV | [M+H]+ | positive | MS2 |
PB001449 | TSQ 7000 | LC-ESI-QQ | ESI | 35 eV | [M+H]+ | positive | MS2 |
NGA00617 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00618 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00619 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00620 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
KO002318 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002319 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002320 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002321 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002322 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
KO008812 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85 | [M+H]+ | positive | MS2 |
KO008814 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.60 | [M+H]+ | positive | MS3 |
KO008815 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.60 | [M+H]+ | positive | MS3 |
KO008813 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.95 | [M+H]+ | positive | MS3 |
KO008817 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.90/0.70 | [M+H]+ | positive | MS4 |
KO008818 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.90/0.75 | [M+H]+ | positive | MS4 |
KO008816 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.90/0.80 | [M+H]+ | positive | MS4 |
CCMSLIB00000847563 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000605 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ000606 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS5 Composite |
VF-NPL-QEHF000874 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000875 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000876 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |