MoNA MS database records for Androstenedione
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU280301 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU280302 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU280303 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU280304 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU280305 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU280306 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 21.1-31.7 eV | [M+H]+ | positive | MS2 |
CB000375 | ABSciex API3200 LC/MS system | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS1 |
CCMSLIB00005723916 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005723917 | qTof | - | - | - | [2M+Na]+ | positive | MS2 |
CCMSLIB00005723918 | qTof | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005723919 | qTof | - | - | - | [M-2H2O+H]+ | positive | MS2 |
CCMSLIB00005723920 | qTof | - | - | - | [2M+H]+ | positive | MS2 |
CCMSLIB00005723921 | qTof | - | - | - | [M+K]+ | positive | MS2 |
FFF00258 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00259 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00260 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00261 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00262 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00263 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00264 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS1 |
FiehnHILIC000193 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnLib000155 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000156 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0000053_c_ms_2118 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0000053_c_ms_2121 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0000053_ei_ms_391 | Leco Pegasus IV | - | - | - | - | - | - |
HMDB0000053_ms_ms_84 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0000053_ms_ms_85 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0000053_ms_ms_86 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
JP005721 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
JP011413 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
LU039601 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU039602 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU039603 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU039604 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU039605 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M+H]+ | positive | MS2 |
MoNA041670 | Agilent 6560 | - | - | 20 | [M+H]+ | positive | - |
MoNA041739 | Agilent 6560 | - | - | 40 | [M+H]+ | positive | - |
SM873201 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416501 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF416502 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF416503 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416504 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |